Literature DB >> 15798417

Correlation of preoperative three-dimensional magnetic resonance angiography with intraoperative findings in laparoscopic renal surgery.

David S Wang1, Alan H Stolpen, Vincent G Bird, Kousei Ishigami, Stephen C Rayhill, Howard N Winfield.   

Abstract

BACKGROUND AND
PURPOSE: Contrast-enhanced three-dimensional magnetic resonance angiography (3D-MRA) with image reconstruction has important applications in laparoscopic urologic surgery. We now use 3D-MRA as part of our preoperative evaluation in selected patients undergoing laparoscopic donor nephrectomy, pyeloplasty, radical nephrectomy, and partial nephrectomy. PATIENTS AND METHODS: From June 2001 to December 2002, 50 patients underwent preoperative 3D-MRA at 1.5 T prior to laparoscopic renal surgery. In general, preoperative 3D-MRA was obtained for donor nephrectomies and pyeloplasties and for cases where prior imaging suggested a possible vascular anomaly. Patients who underwent preoperative imaging included those having donor nephrectomy (N = 28), pyeloplasty (N = 12), radical nephrectomy (N = 5), partial nephrectomy (N = 3), and other laparoscopic renal procedures (N = 2). The 3D-MRA studies were interpreted by one radiologist, and all laparoscopic cases were performed by one of two surgeons. The findings of 3D-MRA were correlated with the intraoperative findings with special attention to aberrant vasculature, including duplicated renal arteries or veins, accessory vessels, or crossing vessels.
RESULTS: Among patients undergoing laparoscopic donor nephrectomy, 3D-MRA correctly predicted the number of renal vessels in 27 of 28 cases (96%), including all 3 cases of left retroaortic renal vein. Also, 3DMRA correctly predicted the presence or absence of a crossing vessel in 10 of 12 cases (83%) of laparoscopic pyeloplasty. The imaging study also correctly predicted the number of hilar vessels in all five cases of radical nephrectomy, all three cases of partial nephrectomy, and both cases of other renal operations. Overall, 3D-MRA correctly defined the renal hilar anatomy in 48 of 50 patients, for an overall accuracy of 96%.
CONCLUSIONS: Three-dimensional MRA findings correlate well (96%) with intraoperative findings in laparoscopic renal surgery. The imaging study provides exquisite vascular detail and is highly accurate, making it sufficient imaging prior to laparoscopic donor nephrectomy and useful for pyeloplasty and other complex renal operations.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15798417     DOI: 10.1089/end.2005.19.193

Source DB:  PubMed          Journal:  J Endourol        ISSN: 0892-7790            Impact factor:   2.942


  2 in total

1.  Study of the left renal variations by means of magnetic resonance imaging.

Authors:  Alper Dilli; Umit Yasar Ayaz; Osman Raif Karabacak; Idil Gunes Tatar; Baki Hekimoglu
Journal:  Surg Radiol Anat       Date:  2011-05-27       Impact factor: 1.246

2.  Real-time navigation by three-dimensional virtual reconstruction models in robot-assisted laparoscopic pyeloplasty for ureteropelvic junction obstruction: our initial experience.

Authors:  Sida Cheng; Xinfei Li; Weijie Zhu; Wanqiang Li; Jie Wang; Jian Yang; Jingyun Wu; He Wang; Lei Zhang; Xuesong Li; Liqun Zhou
Journal:  Transl Androl Urol       Date:  2021-01
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.