Literature DB >> 15798412

Effect of urine specific gravity on effectiveness of shockwave lithotripsy.

Ching-Chia Li1, David S Finley, Carlos Uribe, Louis Eichel, David I Lee, Elspeth M McDougall, Ralph V Clayman.   

Abstract

PURPOSE: To determine the effect of urine specific gravity (SG) and radiographic contrast medium on the efficiency of extracorporeal shockwave lithotripsy (SWL) fragmentation using a previously published in vitro model.
MATERIALS AND METHODS: Artificial kidney stones (BegoStone [BEGO USA, Smithfield, RI]) of a standard size (10 x 10 mm) and weight (mean 1.90 g; range 1.89-1.91 g) were randomly allotted to one of four test media with differing SG: group 1: synthetic urine, SG 1.003; group 2: synthetic urine, SG 1.040; group 3: 50% radiographic contrast (Cysto-Conray II, Mallinckrodt Inc., Hazelwood, MO), 50% synthetic urine, SG 1.069; and group 4: 100% contrast, SG 1.121. The stones were placed in cups made of 2.2-mm screen mesh and exposed to 500 shockwaves at 20 KV from a spark-gap lithotripter (Econolith 2000; Medispec, Germantown, MD). The stone fragmentation rate (i.e., percent fragmentation) was determined by dividing the dry residual stone weight by the prelithotripsy dry weight (X 100).
RESULTS: The mean fragmentation rate for the four groups was 31.7%, 37.6%, 31.8%, and 27.2%, respectively. Statistical significance was not achieved (P = 0.1).
CONCLUSION: Stone breakage tends to be more effective when urine SG is about 1.040 than at higher or lower values. Hence, the recommendation for an overnight fast prior to SWL is well founded. Introduction of contrast medium may inhibit stone breakage because it increases the specific gravity.

Entities:  

Mesh:

Year:  2005        PMID: 15798412     DOI: 10.1089/end.2005.19.167

Source DB:  PubMed          Journal:  J Endourol        ISSN: 0892-7790            Impact factor:   2.942


  3 in total

1.  Ordnance gelatine as an in vitro tissue simulation scaffold for extracorporeal shock wave lithotripsy.

Authors:  C E Mendez-Probst; M Vanjecek; H Razvi; P A Cadieux
Journal:  Urol Res       Date:  2010-10-22

2.  Establishment of Simple and Routine Methods in Early Diagnosis of Gentamicin-Induced Kidney Injury Based on a Rat Model.

Authors:  Cuiyan Liu; Youxi Kang; Huiqin Zhang; Long Zhu; Hai Yu; Chunyang Han
Journal:  Biomed Res Int       Date:  2016-08-18       Impact factor: 3.411

3.  Effect of urine pH on the effectiveness of shock wave lithotripsy: A pilot study.

Authors:  Ahmad Majzoub; Ammar Al-Ani; Tawiz Gul; Hatem Kamkoum; Khalid Al-Jalham
Journal:  Urol Ann       Date:  2016 Jul-Sep
  3 in total