Literature DB >> 15798309

Modelling and validation of spectral reflectance for the colon.

Dzena Hidović-Rowe1, Ela Claridge.   

Abstract

The spectral reflectance of the colon is known to be affected by malignant and pre-malignant changes in the tissue. As part of long-term research on the derivation of diagnostically important parameters characterizing colon histology, we have investigated the effects of the normal histological variability on the remitted spectra. This paper presents a detailed optical model of the normal colon comprising mucosa, submucosa and the smooth muscle layer. Each layer is characterized by five variable histological parameters: the volume fraction of blood, the haemoglobin saturation, the size of the scattering particles, including collagen, the volume fraction of the scattering particles and the layer thickness, and three optical parameters: the anisotropy factor, the refractive index of the medium and the refractive index of the scattering particles. The paper specifies the parameter ranges corresponding to normal colon tissue, including some previously unpublished ones. Diffuse reflectance spectra were modelled using the Monte Carlo method. Validation of the model-generated spectra against measured spectra demonstrated that good correspondence was achieved between the two. The analysis of the effect of the individual histological parameters on the behaviour of the spectra has shown that the spectral variability originates mainly from changes in the mucosa. However, the submucosa and the muscle layer must be included in the model as they have a significant constant effect on the spectral reflectance above 600 nm. The nature of variations in the spectra also suggests that it may be possible to carry out model inversion and to recover parameters characterizing the colon from multi-spectral images. A preliminary study, in which the mucosal blood and collagen parameters were modified to reflect histopathological changes associated with colon cancer, has shown that the spectra predicted by our model resemble measured spectral reflectance of adenocarcinomas. This suggests that an extended model, which incorporates parameters corresponding to an abnormal colon, may be effective for differentiation between normal and cancerous tissues.

Entities:  

Mesh:

Year:  2005        PMID: 15798309     DOI: 10.1088/0031-9155/50/6/003

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  16 in total

1.  Can we see epithelium tissue structure below the surface using an optical probe?

Authors:  Fernand S Cohen; Ezgi Taslidere; Sreekant Murthy
Journal:  Med Biol Eng Comput       Date:  2010-08-31       Impact factor: 2.602

2.  A multimodal spectroscopy system for real-time disease diagnosis.

Authors:  Obrad R Sćepanović; Zoya Volynskaya; Chae-Ryon Kong; Luis H Galindo; Ramachandra R Dasari; Michael S Feld
Journal:  Rev Sci Instrum       Date:  2009-04       Impact factor: 1.523

3.  Model-based spectroscopic analysis of the oral cavity: impact of anatomy.

Authors:  Sasha McGee; Jelena Mirkovic; Vartan Mardirossian; Alphi Elackattu; Chung-Chieh Yu; Sadru Kabani; George Gallagher; Robert Pistey; Luis Galindo; Kamran Badizadegan; Zimmern Wang; Ramachandra Dasari; Michael S Feld; Gregory Grillone
Journal:  J Biomed Opt       Date:  2008 Nov-Dec       Impact factor: 3.170

4.  Monte Carlo model to describe depth selective fluorescence spectra of epithelial tissue: applications for diagnosis of oral precancer.

Authors:  Ina Pavlova; Crystal Redden Weber; Richard A Schwarz; Michelle Williams; Adel El-Naggar; Ann Gillenwater; Rebecca Richards-Kortum
Journal:  J Biomed Opt       Date:  2008 Nov-Dec       Impact factor: 3.170

5.  Impact of vessel diameter and bandwidth of illumination in sidestream dark-field oximetry.

Authors:  Tomohiro Kurata; Zhenguang Li; Shigeto Oda; Hiroshi Kawahira; Hideaki Haneishi
Journal:  Biomed Opt Express       Date:  2015-04-06       Impact factor: 3.732

6.  Anti-confocal assessment of middle ear inflammation.

Authors:  David S Jung; John A Crowe; John P Birchall; Michael G Somekh; Chung W See
Journal:  Biomed Opt Express       Date:  2016-12-12       Impact factor: 3.732

7.  Tissue classification for laparoscopic image understanding based on multispectral texture analysis.

Authors:  Yan Zhang; Sebastian J Wirkert; Justin Iszatt; Hannes Kenngott; Martin Wagner; Benjamin Mayer; Christian Stock; Neil T Clancy; Daniel S Elson; Lena Maier-Hein
Journal:  J Med Imaging (Bellingham)       Date:  2017-01-25

8.  Oblique incidence reflectometry: optical models and measurements using a side-viewing gradient index lens-based endoscopic imaging system.

Authors:  R Andrew Wall; Jennifer K Barton
Journal:  J Biomed Opt       Date:  2014-06       Impact factor: 3.170

9.  In-silico and in-vitro investigation of a photonic monitor for intestinal perfusion and oxygenation.

Authors:  Mitchell B Robinson; Ryan J Butcher; Mark A Wilson; M Nance Ericson; Gerard L Coté
Journal:  Biomed Opt Express       Date:  2017-07-19       Impact factor: 3.732

10.  Trimodal color-fluorescence-polarization endoscopy aided by a tumor selective molecular probe accurately detects flat lesions in colitis-associated cancer.

Authors:  Tauseef Charanya; Timothy York; Sharon Bloch; Gail Sudlow; Kexian Liang; Missael Garcia; Walter J Akers; Deborah Rubin; Viktor Gruev; Samuel Achilefu
Journal:  J Biomed Opt       Date:  2014-12       Impact factor: 3.170

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.