Literature DB >> 15798255

Development of a Monte Carlo model for the Brainlab microMLC.

Jason Belec1, Horacio Patrocinio, Frank Verhaegen.   

Abstract

Stereotactic radiosurgery with several static conformal beams shaped by a micro multileaf collimator (microMLC) is used to treat small irregularly shaped brain lesions. Our goal is to perform Monte Carlo calculations of dose distributions for certain treatment plans as a verification tool. A dedicated microMLC component module for the BEAMnrc code was developed as part of this project and was incorporated in a model of the Varian CL2300 linear accelerator 6 MV photon beam. As an initial validation of the code, the leaf geometry was visualized by tracing particles through the component module and recording their position each time a leaf boundary was crossed. The leaf dimensions were measured and the leaf material density and interleaf air gap were chosen to match the simulated leaf leakage profiles with film measurements in a solid water phantom. A comparison between Monte Carlo calculations and measurements (diode, radiographic film) was performed for square and irregularly shaped fields incident on flat and homogeneous water phantoms. Results show that Monte Carlo calculations agree with measured dose distributions to within 2% and/or 1 mm except for field size smaller than 1.2 cm diameter where agreement is within 5% due to uncertainties in measured output factors.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15798255     DOI: 10.1088/0031-9155/50/5/005

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  8 in total

1.  Analytic IMRT dose calculations utilizing Monte Carlo to predict MLC fluence modulation.

Authors:  I B Mihaylov; F A Lerma; Y Wu; J V Siebers
Journal:  Med Phys       Date:  2006-04       Impact factor: 4.071

2.  Monte Carlo Modeling of the Agility MLC for IMRT and VMAT Calculations.

Authors:  Shingo Ohira; Hideki Takegawa; Masayoshi Miyazaki; Masahiko Koizumi; Teruki Teshima
Journal:  In Vivo       Date:  2020 Sep-Oct       Impact factor: 2.155

3.  The influence of field size on stopping-power ratios in- and out-of-field: quantitative data for the BrainLAB m3 micro-multileaf collimator.

Authors:  Michael Taylor; Tanya Kairn; Tomas Kron; Leon Dunn; Peter N Johnston; Rick D Franich
Journal:  J Appl Clin Med Phys       Date:  2012-11-08       Impact factor: 2.102

4.  Clinical commissioning and use of the Novalis Tx linear accelerator for SRS and SBRT.

Authors:  Jinkoo Kim; Ning Wen; Jian-Yue Jin; Nicole Walls; Sangroh Kim; Haisen Li; Lei Ren; Yimei Huang; Anthony Doemer; Kathleen Faber; Tina Kunkel; Ahssan Balawi; Kimberly Garbarino; Kenneth Levin; Samir Patel; Munther Ajlouni; Brett Miller; Teamor Nurushev; Calvin Huntzinger; Raymond Schulz; Indrin J Chetty; Benjamin Movsas; Samuel Ryu
Journal:  J Appl Clin Med Phys       Date:  2012-05-10       Impact factor: 2.102

5.  Validation of Pinnacle treatment planning system for use with Novalis delivery unit.

Authors:  Vladimir Faygelman; Dylan Hunt; Luke Walker; Richard Mueller; Mary Lou Demarco; Thomas Dilling; Craig Stevens; Geoffrey Zhang
Journal:  J Appl Clin Med Phys       Date:  2010-06-15       Impact factor: 2.102

6.  Development of a dose verification system for Vero4DRT using Monte Carlo method.

Authors:  Yoshitomo Ishihara; Akira Sawada; Mitsuhiro Nakamura; Yuki Miyabe; Hiroaki Tanabe; Shuji Kaneko; Kenji Takayama; Takashi Mizowaki; Masaki Kokubo; Masahiro Hiraoka
Journal:  J Appl Clin Med Phys       Date:  2014-11-08       Impact factor: 2.102

7.  Physical and Dosimetric Aspect of Euromechanics Add-on Multileaf Collimator on Varian Clinac 2100 C/D.

Authors:  S A Rohani; S R Mahdavi; A Mostaar; S Ueltzhöffer; R Mohammadi; Gh Geraily
Journal:  J Biomed Phys Eng       Date:  2019-02-01

8.  Radiation transmission, leakage and beam penumbra measurements of a micro-multileaf collimator using GafChromic EBT film.

Authors:  Olivia Amanda García-Garduño; Miguel Angel Celis; José Manuel Lárraga-Gutiérrez; Sergio Moreno-Jiménez; Arnulfo Martínez-Dávalos; Mercedes Rodríguez-Villafuerte
Journal:  J Appl Clin Med Phys       Date:  2008-06-23       Impact factor: 2.102

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.