Skin doses to patients undergoing coronary angiography in a Greek hospital.

Miltiadis G Delichas1, Kyriakos Psarrakos, Georgios Giannoglou, Elisabeth Molyvda-Athanasopoulou, Konstantinos Hatziioannou, Emmanouil Papanastassiou.   

Abstract

In this study, the skin dose (SD) to patients undergoing coronary angiography (CA) were measured with thermoluminescence dosemeters (TLD) attached to various anatomical locations on the patient's skin during 93 CA procedures in a Greek hospital. The dose-area product (DAP) for every radiological projection was also measured for each procedure. The SD values were measured to be in the range 2.4-427.5 mGy, lower than the 2 Gy dose threshold for transient erythema. No general correlation was observed between the SD and the total DAP.

Entities:  

Mesh:

Year:  2005        PMID: 15797918     DOI: 10.1093/rpd/nch486

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972