Literature DB >> 15797322

A novel continuous subcutaneous lactate monitoring system.

A Poscia1, D Messeri, D Moscone, F Ricci, F Valgimigli.   

Abstract

A novel continuous lactate monitoring system has been developed modifying the GlucoDay portable medical device (A. Menarini Diagnostics), already present in the European market, and used to continuously measure glucose levels. Lactate oxidase based biosensors have been developed immobilising the enzyme on nylon net and placing it on a Pt electrode. The biosensor was connected to the portable device provided with a micro-pump and coupled to a microdialysis system. It is capable to record subcutaneous lactate every 3 min. In vitro analytical results confirmed that the sensors respond linearly in the interval of concentration between 0.1 and 10 mmol/L, covering the whole physiological range. During prolonged monitoring periods, the response of the biosensors remained stable, showing a limited drift of 8%, within 60 h. Stability tests are still on route. However, preliminary results have shown a shelf life of about 10 months. In vivo experiments performed on healthy rabbits have demonstrated the good accuracy and reproducibility of the system. A correlation coefficient equal to 0.9547 (N=80) was found, which represents a good correlation between the GlucoDay and the laboratory reference analyser. A 16 h in vivo monitoring on a healthy volunteer has been also performed.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15797322     DOI: 10.1016/j.bios.2004.10.031

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  5 in total

1.  Accelerated in vitro release testing of implantable PLGA microsphere/PVA hydrogel composite coatings.

Authors:  Jie Shen; Diane J Burgess
Journal:  Int J Pharm       Date:  2011-10-13       Impact factor: 5.875

2.  The 2.1 A structure of Aerococcus viridans L-lactate oxidase (LOX).

Authors:  Ingar Leiros; Ellen Wang; Tonni Rasmussen; Esko Oksanen; Heidi Repo; Steffen B Petersen; Pirkko Heikinheimo; Edward Hough
Journal:  Acta Crystallogr Sect F Struct Biol Cryst Commun       Date:  2006-11-04

Review 3.  Wearable Biosensors: An Alternative and Practical Approach in Healthcare and Disease Monitoring.

Authors:  Atul Sharma; Mihaela Badea; Swapnil Tiwari; Jean Louis Marty
Journal:  Molecules       Date:  2021-02-01       Impact factor: 4.411

4.  Continuous Small-Molecule Monitoring with a Digital Single-Particle Switch.

Authors:  Junhong Yan; Laura van Smeden; Maarten Merkx; Peter Zijlstra; Menno W J Prins
Journal:  ACS Sens       Date:  2020-04-07       Impact factor: 7.711

Review 5.  Fully integrated biochip platforms for advanced healthcare.

Authors:  Sandro Carrara; Sara Ghoreishizadeh; Jacopo Olivo; Irene Taurino; Camilla Baj-Rossi; Andrea Cavallini; Maaike Op de Beeck; Catherine Dehollain; Wayne Burleson; Francis Gabriel Moussy; Anthony Guiseppi-Elie; Giovanni De Micheli
Journal:  Sensors (Basel)       Date:  2012-08-08       Impact factor: 3.576

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.