Literature DB >> 15797267

Reflex vasoconstrictor responses of the healthy human fingertip skin. Normal range, repeatability, and influencing factors.

E P Wilder-Smith1, S Fook-Chong, L Liurong.   

Abstract

Skin vasoconstrictor reflexes (SVCRs) are mediated by sympathetic vasoconstrictor nerve fibers and used to test sympathetic function of the extremities. Since there is a dearth of published systematic data on inspiratory gasp-induced SVCR, we studied its range, repeatability, and influencing factors in 64 healthy subjects (mean age 41.9 years, range 20-78 years, 32 males). Mean vasoconstriction for the second digit was 54% (+/-19)/54% (+/-19) (right/left) and 69% (+/-16)/68% (+/-15) for the fourth digit. Forth digit vasoconstriction was significantly larger than the second digit (P < 0.01), but second and fourth digit correlation was good (Pearson: 0.521-0.741). Repeatability using single measure intraclass correlation was good with 0.62/0.69 for the second digit and 0.64/0.80 for the fourth digit (right/left). A trend for decreasing SVCR was seen with increasing age and weight, no effect was seen for gender, height, or blood pressure. The SVCR repeatability and range of variation seen in this study compare favorably with tests of heart rate variability, thermal threshold detection, and motor nerve conduction.

Entities:  

Mesh:

Year:  2005        PMID: 15797267     DOI: 10.1016/j.mvr.2004.09.001

Source DB:  PubMed          Journal:  Microvasc Res        ISSN: 0026-2862            Impact factor:   3.514


  4 in total

1.  Effect of hand position on digit and ulnar artery vasoconstrictor reflexes.

Authors:  Einar P Wilder-Smith; Linda Liurong; Yaling Guo
Journal:  Clin Auton Res       Date:  2005-08       Impact factor: 4.435

2.  The optimal duration for the wrinkle test in a clinical setting.

Authors:  Erez Grinbaum; Ahmad Shahwan; Amir Eliyahu; Ravit Shay; Nimrod Rozen; Guy Rubin
Journal:  Sci Rep       Date:  2022-05-25       Impact factor: 4.996

3.  Repeatability of the evaluation of systemic microvascular endothelial function using laser doppler perfusion monitoring: clinical and statistical implications.

Authors:  Eduardo Tibiriçá; Alessandra S M Matheus; Bruno Nunes; Sandro Sperandei; Marilia B Gomes
Journal:  Clinics (Sao Paulo)       Date:  2011       Impact factor: 2.365

4.  Early detection of peripheral neuropathy using stimulated skin wrinkling test in human immunodeficiency virus infected patients: A cross-sectional study.

Authors:  Arthur H P Mawuntu; Corry N Mahama; Herlyani Khosama; Riwanti Estiasari; Darma Imran
Journal:  Medicine (Baltimore)       Date:  2018-07       Impact factor: 1.889

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.