Literature DB >> 15797080

Robotic mitral valve annuloplasty with double-arm nitinol U-clips.

Clifton C Reade1, Curtis E Bower, B Marcus Bailey, David M Maziarz, Saqib Masroor, Alan P Kypson, L Wiley Nifong, W Randolph Chitwood.   

Abstract

PURPOSE: Robotic mitral valve repair increases precision however operative times are longer. Prior studies have indicated that robotic knot tying is time consuming and it is without potential room for improvement. We therefore investigated tissue approximation devices that may shorten operative times. DESCRIPTION: A 67-year-old female was approached through a right mini-thoracotomy with the da Vinci Robotic Surgical System (Intuitive Surgical, Sunnyvale, CA). Using 12 nitinol U-clips (Coalescent Surgical, Sunnyvale, CA) an annuloplasty band was placed under robotic guidance. Clip placement and deployment times were recorded and statistical comparisons were assessed to prior suture annuloplasties. EVALUATION: Clip placement time was 1.3 +/- 0.9 (minutes +/- standard deviation), statistical comparison with first, most recent, and all prior suture annuloplasties proving no significance. Clip deployment time was 0.5 +/- 0.2, whereas knot-tying times and respective statistical comparison for first, most recent, and all prior suture annuloplasties were 2.0 +/- 0.7 (p = 0.003), 1.2 +/- 0.4 (p = 0.0004), and 1.6 +/- 0.6 (p < 0.00001). Follow-up echocardiography performed postoperatively, at 3 months, and at 9 months revealed valvular structural integrity with only minimal mitral regurgitation.
CONCLUSIONS: U-clips considerably reduce time for annuloplasty over conventional suture and may help reduce operative times as well.

Entities:  

Mesh:

Year:  2005        PMID: 15797080     DOI: 10.1016/j.athoracsur.2004.02.072

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  3 in total

1.  A robust uniaxial force sensor for minimally invasive surgery.

Authors:  Michael C Yip; Shelten G Yuen; Robert D Howe
Journal:  IEEE Trans Biomed Eng       Date:  2010-02-17       Impact factor: 4.538

Review 2.  Minimally Invasive Cardiovascular Surgery: Incisions and Approaches.

Authors:  Nathaniel B Langer; Michael Argenziano
Journal:  Methodist Debakey Cardiovasc J       Date:  2016 Jan-Mar

3.  A laparoscopic knot-tying device for minimally invasive cardiac surgery.

Authors:  Shaphan R Jernigan; Guillaume Chanoit; Arun Veeramani; Stephen B Owen; Matthew Hilliard; Denis Cormier; Bryan Laffitte; Gregory Buckner
Journal:  Eur J Cardiothorac Surg       Date:  2009-10-24       Impact factor: 4.191

  3 in total