Effects of ceiling-mounted HEPA-UV air filters on airborne bacteria concentrations in an indoor therapy pool building.

Elmira Kujundzic1, David A Zander, Mark Hernandez, Largus T Angenent, David E Henderson, Shelly L Miller.   

Abstract

The purpose of this study was to assess the effectiveness of a new generation of high-volume, ceiling-mounted high-efficiency particulate air (HEPA)-ultraviolet (UV) air filters (HUVAFs) for their ability to remove or inactivate bacterial aerosol. In an environmentally controlled full-scale laboratory chamber (87 m3), and an indoor therapy pool building, the mitigation ability of air filters was assessed by comparing concentrations of total bacteria, culturable bacteria, and airborne endotoxin with and without the air filters operating under otherwise similar conditions. Controlled chamber tests with pure cultures of aerosolized Mycobacterium parafortuitum cells showed that the HUVAF unit tested provided an equivalent air-exchange rate of 11 hr(-1). Using this equivalent air-exchange rate as a design basis, three HUVAFs were installed in an indoor therapy pool building for bioaerosol mitigation, and their effectiveness was studied over a 2-year period. The HUVAFs reduced concentrations of culturable bacteria by 69 and 80% during monitoring periods executed in respective years. The HUVAFs reduced concentrations of total bacteria by 12 and 76% during the same monitoring period, respectively. Airborne endotoxin concentrations were not affected by the HUVAF operation.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15796111     DOI: 10.1080/10473289.2005.10464612

Source DB:  PubMed          Journal:  J Air Waste Manag Assoc        ISSN: 1096-2247            Impact factor:   2.235


  3 in total

1.  Molecular identification of potential pathogens in water and air of a hospital therapy pool.

Authors:  Largus T Angenent; Scott T Kelley; Allison St Amand; Norman R Pace; Mark T Hernandez
Journal:  Proc Natl Acad Sci U S A       Date:  2005-03-15       Impact factor: 11.205

2.  Culture-independent analysis of aerosol microbiology in a metropolitan subway system.

Authors:  Charles E Robertson; Laura K Baumgartner; J Kirk Harris; Kristen L Peterson; Mark J Stevens; Daniel N Frank; Norman R Pace
Journal:  Appl Environ Microbiol       Date:  2013-03-29       Impact factor: 4.792

3.  Air cleaning technologies: an evidence-based analysis.

Authors: 
Journal:  Ont Health Technol Assess Ser       Date:  2005-11-01
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.