Literature DB >> 15795814

The validation of a new method that measures contact and flight times during vertical jump.

J García-López1, J Peleteiro, J A Rodgríguez-Marroyo, J C Morante, J A Herrero, J G Villa.   

Abstract

The aim of this study was to design and validate a vertical jump assessing system based on flight time measurements. Hence, the first phase of this study consisted of programming the software SportJumpv-1.0 and adapting a contact mat and a computer mouse in order to record the flight and contact times of a jump test. In the second phase, 9 subjects made 12 maximal and submaximal vertical single and rebound jumps. Thus 108 flight times and 36 contact times were simultaneously obtained with five different systems: ErgoJump Bosco System (PS), SportJump-v1.0 (SJ), Force Plate (FP), High-speed camera (HSC), and a Led (LED) filmed with a high-speed camera; FP was considered as the reference system. No significant differences were found either between SJ and LED, or between FP and HSC systems. SJ and LED overestimate flight time (9 ms and p < 0.001) and underestimate contact time in respect to FP values. PS underestimates flight time regarding FP values (4 ms and p < 0.01). In spite of the differences obtained between the systems, the errors found are constant. Those slightly depend on the subject's body mass for the systems that are connected to a contact mat. A high correlation between all of them was obtained (r approximately 1 and p < 0.001). The SJ system was validated for an accuracy of 500 Hz, and it was shown to be a useful tool in measuring flight and contact times during jumping. The differences and correlations found between the five systems show that it is necessary to take into account which system is being used when analyzing vertical jump performance.

Entities:  

Mesh:

Year:  2005        PMID: 15795814     DOI: 10.1055/s-2004-820962

Source DB:  PubMed          Journal:  Int J Sports Med        ISSN: 0172-4622            Impact factor:   3.118


  18 in total

1.  The rotor pedaling system improves anaerobic but not aerobic cycling performance in professional cyclists.

Authors:  Jose A Rodríguez-Marroyo; Juan García-López; Karim Chamari; Alfredo Córdova; Olivier Hue; Jose G Villa
Journal:  Eur J Appl Physiol       Date:  2009-01-31       Impact factor: 3.078

2.  Reliability and validity of a wireless microelectromechanicals based system (keimove™) for measuring vertical jumping performance.

Authors:  Bernardo Requena; Inmaculada García; Francisco Requena; Eduardo Saez-Saez de Villarreal; Mati Pääsuke
Journal:  J Sports Sci Med       Date:  2012-03-01       Impact factor: 2.988

3.  Reliability and Validity of the Polar V800 Sports Watch for Estimating Vertical Jump Height.

Authors:  Manuel V Garnacho-Castaño; Marcos Faundez-Zanuy; Noemí Serra-Payá; José L Maté-Muñoz; Josep López-Xarbau; Moisés Vila-Blanch
Journal:  J Sports Sci Med       Date:  2021-03-01       Impact factor: 2.988

4.  Grape extract improves antioxidant status and physical performance in elite male athletes.

Authors:  Sophie Lafay; Caroline Jan; Karine Nardon; Benoit Lemaire; Alvin Ibarra; Marc Roller; Marc Houvenaeghel; Christine Juhel; Louis Cara
Journal:  J Sports Sci Med       Date:  2009-09-01       Impact factor: 2.988

5.  Relationship between vertical jumping performance and anthropometric characteristics during growth in boys and girls.

Authors:  Abdou Temfemo; Jullien Hugues; Karen Chardon; Samuel-Honoré Mandengue; Said Ahmaidi
Journal:  Eur J Pediatr       Date:  2008-07-03       Impact factor: 3.183

6.  Power of counter movement jumps with external load--coherence of three assessment methods.

Authors:  Marie Hilmersson; Ida Edvardsson; Åsa B Tornberg
Journal:  BMC Res Notes       Date:  2015-04-16

7.  Validity Study of a Jump Mat Compared to the Reference Standard Force Plate.

Authors:  Slavko Rogan; Lorenz Radlinger; Caroline Imhasly; Andrea Kneubuehler; Roger Hilfiker
Journal:  Asian J Sports Med       Date:  2015-12-01

8.  Mobile Jump Assessment (mJump): A Descriptive and Inferential Study.

Authors:  Alvaro Mateos-Angulo; Alejandro Galán-Mercant; Antonio Cuesta-Vargas
Journal:  JMIR Rehabil Assist Technol       Date:  2015-08-26

9.  Manifestations of Proprioception During Vertical Jumps to Specific Heights.

Authors:  Artur Struzik; Bogdan Pietraszewski; Adam Kawczyński; Sławomir Winiarski; Grzegorz Juras; Andrzej Rokita
Journal:  J Strength Cond Res       Date:  2017-06       Impact factor: 3.775

10.  Measurement errors when estimating the vertical jump height with flight time using photocell devices: the example of Optojump.

Authors:  A Attia; W Dhahbi; A Chaouachi; J Padulo; D P Wong; K Chamari
Journal:  Biol Sport       Date:  2016-12-01       Impact factor: 2.806

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.