Systemic cross-linked N-terminal telopeptide and procollagen I C-terminal extension peptide as markers of bone turnover after total hip arthroplasty.

L Savarino1, D Granchi, E Cenni, N Baldini, M Greco, A Giunti.   

Abstract

There is no diagnostic, non-invasive method for the early detection of loosening after total hip arthroplasty. In a pilot study, we have analysed two serum markers of bone remodelling, procollagen I C-terminal extension peptide (PICP) and cross-linked N-terminal telopeptide (NTx), as well as the diagnostic performance of NTx for the assessment of osteolysis. We recruited 21 patients with loosening (group I), 18 with a well-fixed prosthesis (group II) and 17 at the time of primary arthroplasty for osteoarthritis (OA) (group III). Internal normal reference ranges were obtained from 30 healthy subjects (group IV). The serum PICP level was found to be significantly lower in patients with OA and those with loosening, when compared with those with stable implants, while the NTx level was significantly increased only in the group with loosening, suggesting that collagen degradation depended on the altered bone turnover induced by the implant. This hypothesis was reinforced by the finding that the values in the pre-surgery patients and stable subjects were comparable with the reference range of younger healthy subjects.A high specificity and positive predictive value for NTx provided good diagnostic evidence of agreement between the test and the clinical and radiological evaluations. The NTx level could be used to indicate stability of the implant. However, further prospective, larger studies are necessary.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15795214     DOI: 10.1302/0301-620X.87B4.15316

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  8 in total

1.  Bone turnover markers correlate with implant fixation in a rat model using LPS-doped particles to induced implant loosening.

Authors:  Shuo Liu; Amarjit S Virdi; Kotaro Sena; W Frank Hughes; Dale R Sumner
Journal:  J Biomed Mater Res A       Date:  2012-01-24       Impact factor: 4.396

2.  Periprosthetic strain magnitude-dependent upregulation of type I collagen synthesis in human osteoblasts through an ERK1/2 pathway.

Authors:  Junfeng Zhu; Xiaoling Zhang; Chengtao Wang; Xiaochun Peng; Xianlong Zhang
Journal:  Int Orthop       Date:  2009-02-12       Impact factor: 3.075

3.  Multiple biomarkers analysis for the early detection of prosthetic aseptic loosening of hip arthroplasty.

Authors:  Tao He; Wen Wu; Yan Huang; Xiaoling Zhang; Tingting Tang; Kerong Dai
Journal:  Int Orthop       Date:  2013-03-07       Impact factor: 3.075

Review 4.  Are there biological markers for wear or corrosion? A systematic review.

Authors:  D Rick Sumner; Ryan Ross; Ed Purdue
Journal:  Clin Orthop Relat Res       Date:  2014-12       Impact factor: 4.176

5.  Biochemical markers of bone turnover in aseptic loosening in hip arthroplasty.

Authors:  Nikolaus A Streich; Tobias Gotterbarm; Martin Jung; Ulrich Schneider; Christian Heisel
Journal:  Int Orthop       Date:  2007-12-15       Impact factor: 3.075

6.  Biomarkers in arthroplasty: a systematic review.

Authors:  Marty T Mertens; Jasvinder A Singh
Journal:  Open Orthop J       Date:  2011-03-16

7.  Bone turnover and periprosthetic bone loss after cementless total hip arthroplasty can be restored by zoledronic acid: a prospective, randomized, open-label, controlled trial.

Authors:  Tsan-Wen Huang; Chao-Jan Wang; Hsin-Nung Shih; Yuhan Chang; Kuo-Chin Huang; Kuo-Ti Peng; Mel S Lee
Journal:  BMC Musculoskelet Disord       Date:  2017-05-22       Impact factor: 2.362

8.  Agarose gel electrophoresis of joint fluid using Hyrys-Hydrasys SEBIA system as a new prognostic tool for periprosthetic osteolysisin revision arthroplasty.

Authors:  A Chiva
Journal:  J Med Life       Date:  2013-09-25
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.