Literature DB >> 15793388

Root surface temperature rises in vitro during root canal obturation using hybrid and microseal techniques.

Mariusz Lipski1.   

Abstract

The aim of this in vitro study was to measure the temperature rise on the outer surface of roots during filling with hybrid technique and Microseal. Twenty extracted human maxillary and mandibular premolars with a single canal were randomly divided into two groups of 10 teeth each. In the first group, the teeth were filled with hybrid technique (thermomechanical compaction with Engine Plugger used following lateral condensation of the apical part of the canal), the second group was filled using Microseal. After root canal obturation the filling material was removed and the obturation procedure was repeated. A total of 20 obturations in each group were performed. Temperature changes were measured using a thermal imaging camera. The temperature of certain regions of the mesial surface was analyzed and the highest temperature values were recorded. Statistical analysis was performed using the Mann-Whitney U test. The mean increase of temperature during the hybrid technique with Engine Plugger was 23.8 degrees C, while during Microseal it was significantly lower (p = 0.000001) at 5.5 degrees C. The temperature rise generated by Microseal was below the critical level and should not damage supporting structures, however, the hybrid technique generated a relatively high temperature rise that may cause periodontal tissue damage.

Entities:  

Mesh:

Year:  2005        PMID: 15793388     DOI: 10.1097/01.don.0000140575.67887.e7

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  4 in total

1.  A Comparative Chemical Study of Calcium Silicate-Containing and Epoxy Resin-Based Root Canal Sealers.

Authors:  Przemysław Reszka; Alicja Nowicka; Mariusz Lipski; Włodzimierz Dura; Agnieszka Droździk; Krzysztof Woźniak
Journal:  Biomed Res Int       Date:  2016-12-20       Impact factor: 3.411

2.  Root Surface Temperature Increases during Root Canal Filling In Vitro with Nd:YAG Laser-Softened Gutta-Percha.

Authors:  Błażej Podolak; Alicja Nowicka; Krzysztof Woźniak; Liliana Szyszka-Sommerfeld; Włodzimierz Dura; Mariusz Borawski; Elżbieta Dembowska; Mariusz Lipski
Journal:  J Healthc Eng       Date:  2020-06-05       Impact factor: 2.682

3.  In Vitro Infrared Thermographic Assessment of Temperature Change in the Pulp Chamber during Provisionalization: Effect of Remaining Dentin Thickness.

Authors:  Mariusz Lipski; Krzysztof Woźniak; Liliana Szyszka-Sommerfeld; Mariusz Borawski; Agnieszka Droździk; Alicja Nowicka
Journal:  J Healthc Eng       Date:  2020-11-10       Impact factor: 2.682

4.  Plugger temperature of cordless heat carriers according to the time elapsed.

Authors:  Hoon-Sang Chang; Se-Hee Park; Kyung-Mo Cho; Jin-Woo Kim
Journal:  Restor Dent Endod       Date:  2018-02-07
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.