Literature DB >> 15792210

Assessment of femoral component migration in total hip arthroplasty: digital measurements compared to RSA.

Uwe Schütz1, Jens Decking, Ralf Decking, Wolfhart Puhl.   

Abstract

The aim of this study was to determine the accuracy of the software system "Düsseldorf Migration Analysis - Femoral Component Analysis" (DMA-FCA) in measuring stem migration in total hip arthroplasty (THA) on digitised anteroposterior radiographs of the pelvis. Bony and implant landmarks on two consecutive radiographs were used for measurements of subsidence and varus-valgus tilt. The accuracy of the method was determined by reference to radiostereometric measurements (RSA). Using specific comparability limits, comparability analysis of radiographs with respect to femoral positioning is possible with DMA. DMA-FCA and RSA measurements were performed after cementless THR in a population of 60 patients aged 38 to 69 years. With a Cronbach's alpha-index of 0.89 and 0.99 for subsidence and 0.90 and 0.98 for classic varus-valgus-tilt, the intraobserver and interobserver reliability for the DMA-FCA-method was calculated as good. Using RSA as reference method, the accuracy of DMA-FCA was calculated to be 2.51 mm for subsidence and 2.49 degrees for varus-valgus-tilt (95% confidence interval). Without comparison to RSA, DMA measured 1.94 mm for subsidence and 2.35 degrees for varus-valgus-tilt. Based on a comparison with RSA, our results show lower accuracy for DMA-FCA than for EBRA-FCA, but DMA-FCA is easier to use in everyday clinical practice. It is hoped that the use of digital measuring methods such as DMA will become standard for long-term observation and will be integrated into clinical routine in the context of quality assurance of THR.

Entities:  

Mesh:

Year:  2005        PMID: 15792210

Source DB:  PubMed          Journal:  Acta Orthop Belg        ISSN: 0001-6462            Impact factor:   0.500


  5 in total

1.  High incidence of migration with poor initial fixation of the Accolade stem.

Authors:  Craig A White; Sasha Carsen; Kevin Rasuli; Robert J Feibel; Paul R Kim; Paul E Beaulé
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

2.  Deep Learning for Radiographic Measurement of Femoral Component Subsidence Following Total Hip Arthroplasty.

Authors:  Pouria Rouzrokh; Cody C Wyles; Shyam J Kurian; Taghi Ramazanian; Jason C Cai; Qiao Huang; Kuan Zhang; Michael J Taunton; Hilal Maradit Kremers; Bradley J Erickson
Journal:  Radiol Artif Intell       Date:  2022-05-04

3.  Radiographic Subsidence in Asymptomatic Patients After THR Using the Furlong Active HAP Stem.

Authors:  José Cordero-Ampuero; Pablo Peñalver; Rodrigo Antón; María Galán; Enrique Cordero
Journal:  HSS J       Date:  2013-06-21

4.  Cemented Exeter total hip arthroplasty with a 32 mm head on highly crosslinked polyethylene: Does age influence functional outcome, satisfaction, activity, stem migration, and periprosthetic bone mineral density?

Authors:  N D Clement; M Bardgett; K Merrie; S Furtado; R Bowman; D J Langton; D J Deehan; J Holland
Journal:  Bone Joint Res       Date:  2019-07-05       Impact factor: 5.853

5.  Preliminary outcomes of the cementless UNITED hip system for primary total hip arthroplasty at a minimum 2-year follow-up.

Authors:  Fernando Díaz-Dilernia; Agustín M García-Mansilla; Agustín Albani-Forneris; Pablo A Slullitel; Gerardo Zanotti; Fernando Comba; Francisco Piccaluga; Martin Buttaro
Journal:  Eur J Orthop Surg Traumatol       Date:  2021-06-12
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.