Literature DB >> 15792177

Reduction of the QT interval dispersion after aortic valve replacement reflects changes in electrical function rather than structural remodeling.

Ewa Orlowska-Baranowska1, Rafal Baranowski, Beata Kusmierczyk, Janina Sepiska.   

Abstract

BACKGROUND AND AIM OF THE STUDY: Factors related to changes of QT dispersion (QTd) after aortic valve replacement (AVR) in patients with aortic stenosis were analyzed.
METHODS: The prospective group comprised 121 consecutive patients (45 women, 76 men; mean age 58 +/- 11 years; range: 24-77 years) with significant aortic valve stenosis. Data (clinical, echocardiographic and electrocardiographic) were collected before and at least 16 months after AVR. QTd was measured in the standard ECG.
RESULTS: Before AVR, the mean QTd was 60 +/- 24 ms (QT(max) 424 +/- 40 ms). QTd was > 50 ms in 68% of patients, and > 70 ms in 30%. During postoperative follow up the mean QTd was 54 +/- 19 ms (QT(max) 368 +/- 36 ms) for all patients, and was > 50 ms in 58% of cases and > 70 ms in 13%. Postoperatively, QTd was decreased to < 70 ms in 27% of patients with a normalized left ventricular mass index (LVMI), and in 27% of those without any clinically significant reduction in left ventricular (LV) hypertrophy. In the multivariate analysis, QTd reduction was weakly related to the reduction in LV wall thickness (p = 0.09) and LVMI (p = 0.05). The reduction in QTd was more related to changes in T-wave amplitude in lead V5 (p = 0.004).
CONCLUSION: Following AVR for aortic stenosis, a decrease in QTd was observed, notably among patients with QTd > 70 ms. This reduction was only weakly related to the degree of reduction in cardiac hypertrophy, but a more important relationship was observed with changes in T-wave amplitude. These findings suggest that a reduction in QTd after AVR is reflective of changes in electrical function rather than structural remodeling.

Entities:  

Mesh:

Year:  2005        PMID: 15792177

Source DB:  PubMed          Journal:  J Heart Valve Dis        ISSN: 0966-8519


  4 in total

1.  Diagnostic value of combined parameters derived from ambulatory electrocardiography for detecting coronary artery disease in non-active chest pain patients.

Authors:  Yue Jiang; Jun-Ping Tian; Hong Wang; Bu-Xing Chen; Feng-He Du
Journal:  Pak J Med Sci       Date:  2014 Nov-Dec       Impact factor: 1.088

2.  Effect of transcatheter aortic valve implantation on QT dispersion in patients with aortic stenosis.

Authors:  Hakan Erkan; Engin Hatem; Mustafa Tarık Ağaç; Levent Korkmaz; Teyyar Gökdeniz; Ahmet Çağrı Aykan; Ezgi Kalaycıoğlu; Faruk Boyacı; Ömer Faruk Çırakoğlu; Şükrü Çelik
Journal:  J Geriatr Cardiol       Date:  2014-12       Impact factor: 3.327

3.  A 24-hour ambulatory ecg monitoring in assessment of qt interval duration and dispersion in rowers with physiological myocardial hypertrophy.

Authors:  I Y Lutfullin; Z F Kim; R R Bilalova; N A Tsibulkin; R R Almetova; R R Mudarisova; I I Ahmetov
Journal:  Biol Sport       Date:  2013-11-25       Impact factor: 2.806

4.  QT Dispersion Changes after Transcatheter Aortic Valve Implantation in Patients with Aortic Stenosis.

Authors:  Mustafa Zungur
Journal:  Braz J Cardiovasc Surg       Date:  2019-12-01
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.