Literature DB >> 15791288

The Gurvich waveform has lower defibrillation threshold than the rectilinear waveform and the truncated exponential waveform in the rabbit heart.

Fujian Qu1, Fidel Zarubin, Brian Wollenzier, Vladimir P Nikolski, Igor R Efimov.   

Abstract

Implantable cardioverter defibrillator studies have established the superiority of biphasic waveforms over monophasic waveforms. However, external defibrillator studies of biphasic waveforms are not as widespread. Our objective was to compare the defibrillation efficacy of clinically used biphasic waveforms, i.e., truncated exponential, rectilinear, and quasi-sinusoidal (Gurvich) waveforms in a fibrillating heart model. Langendorff-perfused rabbit hearts (n = 10) were stained with a voltage-sensitive fluorescent dye, Di-4-ANEPPS. Transmembrane action potentials were optically mapped from the anterior epicardium. We found that the Gurvich waveform was significantly superior (p < 0.05) to the rectilinear and truncated exponential waveforms. The defibrillation thresholds (mean +/- SE) were as follows: Gurvich, 0.25 +/- 0.01 J; rectilinear-1, 0.34 +/- 0.01 J; rectilinear-2, 0.33 +/- 0.01 J; and truncated exponential, 0.32 +/- 0.02 J. Using optically recorded transmembrane responses, we determined the shock-response transfer function, which allowed us to predict the cellular response to waveforms at high accuracy. The passive parallel resistor-capacitor model (RC-model) predicted polarization superiority of the Gurvich waveform in the myocardium with a membrane time constant (taum) of less than 2 ms. The finding of a lower defibrillation threshold with the Gurvich waveform in an in vitro model of external defibrillation suggests that the Gurvich waveform may be important for future external defibrillator designs.

Entities:  

Mesh:

Year:  2005        PMID: 15791288     DOI: 10.1139/y04-131

Source DB:  PubMed          Journal:  Can J Physiol Pharmacol        ISSN: 0008-4212            Impact factor:   2.273


  3 in total

1.  Energy-efficient waveform shapes for neural stimulation revealed with a genetic algorithm.

Authors:  Amorn Wongsarnpigoon; Warren M Grill
Journal:  J Neural Eng       Date:  2010-06-23       Impact factor: 5.379

Review 2.  Cardiac optogenetics.

Authors:  Emilia Entcheva
Journal:  Am J Physiol Heart Circ Physiol       Date:  2013-03-01       Impact factor: 4.733

3.  Ascending-ramp biphasic waveform has a lower defibrillation threshold and releases less troponin I than a truncated exponential biphasic waveform.

Authors:  Jian Huang; Gregory P Walcott; Richard B Ruse; Scott J Bohanan; Cheryl R Killingsworth; Raymond E Ideker
Journal:  Circulation       Date:  2012-08-03       Impact factor: 29.690

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.