Literature DB >> 15789588

Effects of region-of-interest length on estimates of myocardial ultrasonic attenuation and backscatter.

Steven L Baldwin1, Mark R Holland, David E Sosnovik, James G Miller.   

Abstract

Measurements of tissue properties using an image-based technique that makes use of an external reference may have the potential for practical clinical implementation in echocardiography. The objective of this study was to quantify the ability of this technique to distinguish myocardial attenuation and backscatter properties for specific lengths of the region-of-interest (ROI). We chose to exploit the anisotropic properties of the myocardium as a model for distinguishing tissue with different acoustic properties. Excised lateral wall segments from seven healthy adult sheep hearts were imaged using a commercially available (Philips/ATL) clinical scanner operating in the fundamental imaging mode with a linear array (L 7-4). Statistical and receiver operating characteristic (ROC) analyses were used to evaluate the ability of the video signal analysis method to differentiate midmyocardial from subendocardial regions based on measurements of the acoustic properties for specific lengths of the ROI. Results demonstrate that the ability to distinguish tissue properties increases with ROI length for both slope of attenuation and backscatter coefficient measurements. Statistically significant differences were observed for measurements utilizing the ROI lengths as short as 0.4 cm with corresponding progressively increasing areas under the ROC curves for increasing ROI lengths. [NIH R37 HL40302]

Entities:  

Mesh:

Year:  2005        PMID: 15789588     DOI: 10.1118/1.1852793

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  2 in total

1.  Ultrasonic Assessment of Myocardial Microstructure in Hypertrophic Cardiomyopathy Sarcomere Mutation Carriers With and Without Left Ventricular Hypertrophy.

Authors:  Pranoti Hiremath; Patrick R Lawler; Jennifer E Ho; Andrew W Correia; Siddique A Abbasi; Raymond Y Kwong; Michael Jerosch-Herold; Carolyn Y Ho; Susan Cheng
Journal:  Circ Heart Fail       Date:  2016-09       Impact factor: 8.790

2.  Toward 3-D Echocardiographic Determination of Regional Myofiber Structure.

Authors:  Michelle L Milne; Gautam K Singh; James G Miller; Kirk D Wallace; Mark R Holland
Journal:  Ultrasound Med Biol       Date:  2015-11-14       Impact factor: 2.998

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.