Literature DB >> 15786902

Oral insertion of a flexible bronchoscope is associated with less discomfort than nasal insertion for Korean patients.

C M Choi1, H I Yoon, S M Lee, C-G Yoo, Y W Kim, S K Han, Y-S Shim, J-J Yim.   

Abstract

OBJECTIVE: The route of bronchoscope insertion varies between centres, without a firm rationale based on well-designed studies. We therefore compared nasal and oral insertion of a flexible bronchoscope and evaluated efficacy and patient satisfaction.
DESIGN: Prospective randomised study of patients who underwent flexible bronchoscopy from May to September 2003 and who were randomly assigned to nasal and oral insertion approaches.
RESULTS: Clinical characteristics, factors related to the procedure and patient satisfaction were analysed. In total, 307 patients were randomly assigned to the nasal (n = 158) or oral insertion groups (n = 149). No difference in baseline characteristics was identified between the groups. Insertion by the oral route was associated with a smaller amount of lidocaine use during the procedure (P = 0.04) and less frequent insertion site bleeding (P = 0.005). Patients assigned to oral insertion reported less discomfort during anaesthesia (P = 0.01) and scope insertion (P < 0.001), as well as less dyspnoea (P = 0.04) and coughing (P = 0.03).
CONCLUSION: Oral insertion of a flexible bronchoscope was associated with less discomfort for patients than nasal insertion, although the route of insertion had no significant effect on outcome.

Entities:  

Mesh:

Year:  2005        PMID: 15786902

Source DB:  PubMed          Journal:  Int J Tuberc Lung Dis        ISSN: 1027-3719            Impact factor:   2.373


  7 in total

1.  Feasibility of using the nasal route for linear endobronchial ultrasound.

Authors:  Stéphane Beaudoin; Nancy Ferland; Simon Martel; Antoine Delage
Journal:  Lung       Date:  2014-08-14       Impact factor: 2.584

2.  Influence of additional post-bronchoscopy visit on patient satisfaction after flexible bronchoscopy.

Authors:  Jong Sun Park; Jeong-Seon Ryu; Sang-Min Lee; Jae-Joon Yim; Chul-Gyu Yoo; Young Whan Kim; Sung Koo Han; Young-Soo Shim; Seok-Chul Yang
Journal:  Korean J Intern Med       Date:  2010-11-27       Impact factor: 3.165

Review 3.  Complications and discomfort of bronchoscopy: a systematic review.

Authors:  Elise Orvedal Leiten; Einar Marius Hjellestad Martinsen; Per Sigvald Bakke; Tomas Mikal Lind Eagan; Rune Grønseth
Journal:  Eur Clin Respir J       Date:  2016-11-11

4.  A Prospective Observational Study on the Tolerability of Transnasal Bronchoscopy With a Surgical Mask for Aerosol Control.

Authors:  Yusuke Usui; Shinji Sasada; Keisuke Kirita; Sayaka Nagayama; Saori Murata; Yumi Tsuchiya; Kota Ishioka; Saeko Takahashi; Morio Nakamura; Kazuma Kishi
Journal:  Cureus       Date:  2022-08-20

5.  Nasal route for endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA): An alternative modality in difficult oral bronchoscope insertion.

Authors:  Saurabh Mittal; Karan Madan; Vijay Hadda; Anant Mohan; Randeep Guleria
Journal:  Lung India       Date:  2017 Sep-Oct

6.  Factors affecting patients' comfort during fiberoptic bronchoscopy and endobronchial ultrasound.

Authors:  Fatma Yıldırım; Şevket Özkaya; Ahmet Selim Yurdakul
Journal:  J Pain Res       Date:  2017-03-29       Impact factor: 3.133

7.  1% versus 2% lignocaine for airway anesthesia in endobronchial ultrasound-guided transbronchial needle aspiration: A pilot, double-blind, randomized controlled trial.

Authors:  Shiba Kalyan Biswal; Saurabh Mittal; Vijay Hadda; Anant Mohan; Gopi C Khilnani; Ravindra M Pandey; Randeep Guleria; Karan Madan
Journal:  Lung India       Date:  2018 Nov-Dec
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.