Literature DB >> 15786749

CT-guided automated cutting needle biopsy by a combined method for accurate specific diagnosis of focal lung lesions.

Shiro Satoh1, Shinichi Ohdama, Osamu Matsubara, Yasumi Okochi, Rei Tanaka, Yuji Kimula.   

Abstract

PURPOSE: The purpose of our study was to evaluate a method of automated cutting needle biopsy (ACNB) that combines the use of a long-throw needle, higher mean number of needle passes, and tandem system, in terms of the accuracy of specific diagnosis of small and large lung lesions and the safety of the procedure.
MATERIALS AND METHODS: Fifty-seven ACNBs were performed under computed tomography guidance using a tandem system with a 20-gauge and 18-gauge (through non-aerated lung) automated cutting needle with a throw length of 23 mm. We classified the nodules into 21 small nodules (< or =2 cm) and 36 large nodules (>2 cm). All ACNB diagnoses were divided into three groups: specific, non-specific, and false diagnoses. All of the complications were recorded.
RESULTS: The mean number of ACNB specimens obtained was 2.0. Of the 35 ACNB procedures for malignant lesions, 33 yielded a specific malignant diagnosis (33/35, 94%). Of the 22 procedures for benign lesions, 17 gave a specific benign diagnosis (17/22, 77%). The diagnostic accuracy for small nodules was no lower than that for large nodules. Postbiopsy pneumothorax occurred in 18 patients (32%).
CONCLUSION: The diagnostic accuracy of the combined method is as high for small lung nodules as for large ones. The procedure has high diagnostic accuracy for the subtypes of lung cancer and an acceptable complication rate.

Entities:  

Mesh:

Year:  2005        PMID: 15786749

Source DB:  PubMed          Journal:  Radiat Med        ISSN: 0288-2043


  3 in total

1.  CT-guided thoracic core biopsies: value of a negative result.

Authors:  Leslie E Quint; Matthew Kretschmer; Andrew Chang; Bin Nan
Journal:  Cancer Imaging       Date:  2006-11-08       Impact factor: 3.909

Review 2.  Complication rates of CT-guided transthoracic lung biopsy: meta-analysis.

Authors:  W J Heerink; G H de Bock; G J de Jonge; H J M Groen; R Vliegenthart; M Oudkerk
Journal:  Eur Radiol       Date:  2016-04-23       Impact factor: 5.315

3.  Non-diagnostic Results of Percutaneous Transthoracic Needle Biopsy: A Meta-analysis.

Authors:  Kum Ju Chae; Hyunsook Hong; Soon Ho Yoon; Seokyung Hahn; Gong Yong Jin; Chang Min Park; Jin Mo Goo
Journal:  Sci Rep       Date:  2019-08-27       Impact factor: 4.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.