Sovering annuloplasty rings: experimental pathology in the sheep model.

Mila Della Barbera1, François Laborde, Gaetano Thiene, Valter Arata, Elena Pettenazzo, Enrico Pasquino, Luc Behr, Marialuisa Valente.   

Abstract

INTRODUCTION: A new flexible annuloplasty ring (Sovering, Sorin Biomedica Cardio), both closed and open, has been designed and consists of radiopaque silicone core impregnated with barium sulfate and covered by a knitted polyester fabric coated with Carbofilm. The aim of the study was to test the biological compatibility of the new device in large animals in orthotopic position.
METHODS: Ten Sovering rings were implanted in 10 female adult sheep, 7 mitral (3 open, 4 closed) and 3 tricuspid (all open). The size was 23-25 mm in the mitral and 28-30 mm in the tricuspid position, and the time in place varied from 63 to 110 days (mean = 89 +/- 14) and from 58 to 63 days (mean = 61 +/- 3), respectively. The morphological analysis consisted of gross, histological, immunohistochemical and ultrastructural investigations.
RESULTS: The prosthetic ring appeared well implanted in the valve atrioventricular (AV) junction, encapsulated by a thin fibrous sheath without any evidence of thrombus deposition, fibrinous lining or exuberant fibrous tissue overgrowth. No adverse inflammatory reaction was observed, but rare lymphocytes, macrophages and foreign body giant cells. At electron microscopy, the fibrous tissue appeared to permeate deeply within the fabric network; reendothelization on the surface was noted and confirmed by immunohistochemistry. Sirius red staining at polarized light revealed a higher content of collagen type III in the mitral than in the tricuspid position.
CONCLUSIONS: Sovering annuloplasty rings implanted in the AV valves of adult sheep showed excellent biocompatibility, fibrous encapsulation and reendothelization. The absence of thrombosis and exuberant fibrous tissue reaction supports the effective use of Carbofilm covering in annuloplasty devices.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15780801     DOI: 10.1016/j.carpath.2004.12.005

Source DB:  PubMed          Journal:  Cardiovasc Pathol        ISSN: 1054-8807            Impact factor:   2.185


  3 in total

1.  Efficacy of polymer injection for ischemic mitral regurgitation: persistent reduction of mitral regurgitation and attenuation of left ventricular remodeling.

Authors:  Xin Zeng; Lin Zou; Robert A Levine; J Luis Guerrero; Mark D Handschumacher; Suzanne M Sullivan; Gavin J C Braithwaite; James R Stone; Jorge Solis; Orhun K Muratoglu; Gus J Vlahakes; Judy Hung
Journal:  JACC Cardiovasc Interv       Date:  2015-01-14       Impact factor: 11.195

2.  Comparison of the novel Medtentia double helix mitral annuloplasty system with the Carpentier-Edwards Physio annuloplasty ring: morphological and functional long-term outcome in a mitral valve insufficiency sheep model.

Authors:  Moritz A Konerding; Jarmo Simpanen; Leo Ihlberg; Juha Aittomäki; Kalervo Werkkala; Vera Delventhal; Maximilian Ackermann
Journal:  J Cardiothorac Surg       Date:  2013-04-08       Impact factor: 1.637

3.  Clinical outcomes of tricuspid valve repair accompanying left-sided heart disease.

Authors:  Kasra Azarnoush; Ahmad S Nadeemy; Bruno Pereira; Massoud A Leesar; Céline Lambert; Alaa Azhari; Vedat Eljezi; Nicolas Dauphin; Etienne Geoffroy; Lionel Camilleri
Journal:  World J Cardiol       Date:  2017-10-26
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.