Literature DB >> 15779628

Functional adaptation of articular cartilage from birth to maturity under the influence of loading: a biomechanical analysis.

H Brommer1, P A J Brama, M S Laasanen, H J Helminen, P R van Weeren, J S Jurvelin.   

Abstract

REASONS FOR PERFORMING STUDY: The concept of functional adapatation of articular cartilage during maturation has emerged from earlier biochemical research. However, articular cartilage has principally a biomechanical function governed by joint loading.
OBJECTIVES: To verify whether the concept of functional adaptation can be confirmed by direct measurement of biomechanical properties of cartilage. HYPOTHESIS: Fetuses have homogeneous (i.e. site-independent) cartilage with regard to biomechanical properties. During growth and development to maturity, the biomechanical characteristics adapt according to functional (loading) demands, leading to distinct, site-dependent biomechanical heterogeneity of articular cartilage.
METHODS: Osteochondral plugs were drilled out of the surface at 2 differently loaded sites (Site 1: intermittent impact-loading during locomotion, Site 2: low-level constant loading during weightbearing) of the proximal articular cartilage surface of the proximal phalanx in the forelimb from stillborn foals (n = 8), horses of age 5 (n = 9) and 18 months (n = 9) and mature horses (n = 13). Cartilage thickness was measured using ultrasonic, optical and needle-probe techniques. The osteochondral samples were biomechanically tested in indentation geometry. Young's modulus at equilibrium, dynamic modulus at 1 Hz and the ratios of these moduli values between Sites 1 and 2 were calculated. Age and site effects were evaluated statistically using ANOVA tests. The level of significance was set at P<0.05.
RESULTS: Fetal cartilage was significantly thicker compared to the other ages with no further age-dependent differences in cartilage thickness from age 5 months onwards. Young's modulus stayed constant at Site 1, whereas at Site 2 there was a gradual, statistically significant increase in modulus during maturation. Values of dynamic modulus at both Sites 1 and 2 were significantly higher in the fetus and decreased after birth. Values for both moduli were significantly different between Sites 1 and 2 from age 18 months onwards. The ratio of values between Sites 1 and 2 for Young's modulus and dynamic modulus showed a gradual decrease from approximately 1.0 at birth to 0.5-0.6 in the mature horse. At age 18 months, all values were comparable to those in the mature horse.
CONCLUSIONS: In line with the concept of functional adaptation, the neonate is born with biomechanically 'blank' or homogeneous cartilage. Functional adaptation of biomechanical properties takes place early in life, resulting in cartilage with a distinct heterogeneity in functional characteristics. At age 18 months, functional adaptation, as assessed by the biomechanical characteristics, has progressed to a level comparable to the mature horse and, after this age, no major adaptations seem to occur. POTENTIAL RELEVANCE: Throughout life, different areas of articular cartilage are subjected to different types of loading. Differences in loading can adequately be met only when the tissue is biomechanically adapted to withstand these different loading conditions without injury. This process of functional adaptation starts immediately after birth and is completed well before maturity. This makes the factor of loading at a young age a crucial variable, and emphasises the necessity to optimise joint loading during early life in order to create an optimal biomechanical quality of articular cartilage, which may well turn out to be the best prevention for joint injury later in life.

Entities:  

Mesh:

Year:  2005        PMID: 15779628     DOI: 10.2746/0425164054223769

Source DB:  PubMed          Journal:  Equine Vet J        ISSN: 0425-1644            Impact factor:   2.888


  28 in total

1.  Structure-function relationships of fetal ovine articular cartilage.

Authors:  Wendy E Brown; Grayson D DuRaine; Jerry C Hu; Kyriacos A Athanasiou
Journal:  Acta Biomater       Date:  2019-02-01       Impact factor: 8.947

2.  Force scanning: a rapid, high-resolution approach for spatial mechanical property mapping.

Authors:  E M Darling
Journal:  Nanotechnology       Date:  2011-03-16       Impact factor: 3.874

3.  Intrinsic repair of full-thickness articular cartilage defects in the axolotl salamander.

Authors:  R S Cosden; C Lattermann; S Romine; J Gao; S R Voss; J N MacLeod
Journal:  Osteoarthritis Cartilage       Date:  2010-11-27       Impact factor: 6.576

4.  Morphological, biochemical and mechanical properties of articular cartilage and subchondral bone in rat tibial plateau are age related.

Authors:  Pengling Ren; Haijun Niu; He Gong; Rui Zhang; Yubo Fan
Journal:  J Anat       Date:  2017-12-20       Impact factor: 2.610

5.  Changes in mechanics and composition of human talar cartilage anlagen during fetal development.

Authors:  R Mahmoodian; J Leasure; P Philip; N Pleshko; F Capaldi; S Siegler
Journal:  Osteoarthritis Cartilage       Date:  2011-07-29       Impact factor: 6.576

6.  Oxidant conditioning protects cartilage from mechanically induced damage.

Authors:  Prem Ramakrishnan; Benjamin A Hecht; Douglas R Pedersen; Matthew R Lavery; Jerry Maynard; Joseph A Buckwalter; James A Martin
Journal:  J Orthop Res       Date:  2010-07       Impact factor: 3.494

7.  Postnatal development of collagen structure in ovine articular cartilage.

Authors:  Mark C van Turnhout; Henk Schipper; Bas Engel; Willem Buist; Sander Kranenbarg; Johan L van Leeuwen
Journal:  BMC Dev Biol       Date:  2010-06-07       Impact factor: 1.978

8.  Quantitative assessment of articular cartilage morphology via EPIC-microCT.

Authors:  L Xie; A S P Lin; M E Levenston; R E Guldberg
Journal:  Osteoarthritis Cartilage       Date:  2008-09-11       Impact factor: 6.576

9.  Functional MRI can detect changes in intratissue strains in a full thickness and critical sized ovine cartilage defect model.

Authors:  Deva D Chan; Luyao Cai; Kent D Butz; Eric A Nauman; Darryl A Dickerson; Ilse Jonkers; Corey P Neu
Journal:  J Biomech       Date:  2017-11-21       Impact factor: 2.712

10.  An in-situ fluorescence-based optical extensometry system for imaging mechanically loaded bone.

Authors:  Christopher Price; Wen Li; John E Novotny; Liyun Wang
Journal:  J Orthop Res       Date:  2010-06       Impact factor: 3.494

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.