Literature DB >> 15779317

Microtensile bond strength of self-etching adhesives to enamel and dentin.

Cecilia Goracci1, Fernanda Tranchesi Sadek, Francesca Monticelli, Paulo Eduardo Capel Cardoso, Marco Ferrari.   

Abstract

PURPOSE: To measure the microtensile bond strength to enamel and dentin of three self-etching adhesives in comparison with a total-etch two-step system as a control.
MATERIALS AND METHODS: A total of 40 extracted human molars were stored in saline solution until use, then divided into 4 groups of 10 teeth (one group per adhesive system). Half of each of these groups underwent bond strength tests on enamel, and the other half was used for adhesion testing on dentin. The following experimental groups (n = 5) were then formed: E(1) Adper Prompt-L-Pop (AP, 3M ESPE) on enamel; E(2) Xeno CF II (X, Sanking Kogyo) on enamel; E(3) AdheSE (AS, Ivoclar-Vivadent) on enamel; E(4) Excite (EX, Ivoclar-Vivadent) on enamel; D(1) AP on dentin; D(2): X on dentin; D(3) AS on dentin; D(4) EX on dentin. Each tooth yielded 15 to 20 sticks about 0.9 x 0.9 mm in cross-sectional area for microtensile testing. Specimens were loaded in tension at a crosshead speed of 0.5 mm/minute, and bond strength at failure was calculated in MPa. A two-way ANOVA was applied to test for significance of the differences among the groups.
RESULTS: The bond strength values of Excite (the control) were significantly higher than those of the test products on enamel (42.92+/-4.8 MPa) and on dentin (45.80+/-5.79 MPa). The self-etching adhesives AdheSE (28.48+/-4.71 MPa) and Xeno CF II (27.22+/-2.74 MPa) revealed significantly stronger adhesion than Adper Prompt-L-Pop (20.16+/-2.07 MPa) on dentin. On enamel, all self-etching test materials performed similarly. The substrate did not appear to have a significant influence on adhesion, as each material reached comparable levels of bond strength on enamel and dentin.
CONCLUSION: On both substrates the self-etching adhesives tested performed significantly worse than did the total-etch system.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15779317

Source DB:  PubMed          Journal:  J Adhes Dent        ISSN: 1461-5185            Impact factor:   2.359


  8 in total

1.  Clinical longevity of ceramic laminate veneers bonded to teeth with and without existing composite restorations up to 40 months.

Authors:  Marco M M Gresnigt; Warner Kalk; Mutlu Özcan
Journal:  Clin Oral Investig       Date:  2012-07-21       Impact factor: 3.573

2.  Effect of EDTA and phosphoric Acid pretreatment on the bonding effectiveness of self-etch adhesives to ground enamel.

Authors:  Ihab M Ibrahim; Dina W Elkassas; Mai M Yousry
Journal:  Eur J Dent       Date:  2010-10

3.  Effect of storage environment on the bond strength of reattachment of crown fragments to fractured teeth.

Authors:  Farzaneh Shirani; Mohammad Reza Malekipour; Dana Tahririan; Vahid Sakhaei Manesh
Journal:  J Conserv Dent       Date:  2011-07

4.  The Micro-Shear bond strength of different cements to commercially pure titanium.

Authors:  Mohammadreza Nakhaei; Zeinab Fendereski; Samin Alavi; Hamideh-Sadat Mohammadipour
Journal:  J Clin Exp Dent       Date:  2019-09-01

5.  Growth factor release and dental pulp stem cell attachment following dentine conditioning: An in vitro study.

Authors:  Leili Sadaghiani; Abdullah M Alshumrani; Hannah B Gleeson; Wayne Nishio Ayre; Alastair J Sloan
Journal:  Int Endod J       Date:  2022-06-16       Impact factor: 5.165

Review 6.  Current perspectives on dental adhesion: (1) Dentin adhesion - not there yet.

Authors:  Jorge Perdigão
Journal:  Jpn Dent Sci Rev       Date:  2020-09-23

7.  Shear bond strengths and morphological evaluation of filled and unfilled adhesive interfaces to enamel and dentine.

Authors:  Vajihesadat Mortazavi; Mohammadhosein Fathi; Ebrahim Ataei; Niloufar Khodaeian; Navid Askari
Journal:  Int J Dent       Date:  2012-11-06

8.  Influence of erbium, chromium-doped: Yttrium scandium-gallium-garnet laser etching and traditional etching systems on depth of resin penetration in enamel: A confocal laser scanning electron microscope study.

Authors:  Vishal Vijayan; K Rajasigamani; K Karthik; Sasidharan Maroli; Jitesh Chakkarayan; Mohamed Haris
Journal:  J Pharm Bioallied Sci       Date:  2015-08
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.