Literature DB >> 15777786

Reversible and repeatable linear local cell force response under large stretches.

Shengyuan Yang1, Taher Saif.   

Abstract

Large stretching and un-stretching force response of adherent fibroblasts is measured by micromachined mechanical force sensors. The force sensors are composed of a probe and flexible beams. The probe, functionalized by fibronectin, is used to contact the cells. The flexible beams are the sensing element. The sensors are made of single crystal silicon and fabricated by the SCREAM process. The maximum cell stretch reached is approximately 50 microm, which is about twice of the cell initial size, and the time delay between two consecutive stretching/un-stretching steps is 75 s unless otherwise stated. We find that the force response of the cells is strongly linear, reversible, and repeatable, with a small stiffening at the initial deformation stage. Force response of single cells measured before and after cytochalasin D treatment suggests that actin filaments take almost all the cell internal forces due to stretch. These findings may shed light on the increasing understanding on the mechanical behavior of cells and provide clues for making new classes of biological materials having uncommon properties.

Entities:  

Mesh:

Year:  2005        PMID: 15777786     DOI: 10.1016/j.yexcr.2004.12.026

Source DB:  PubMed          Journal:  Exp Cell Res        ISSN: 0014-4827            Impact factor:   3.905


  6 in total

1.  Relax? Don't do it!-Linking presynaptic vesicle clustering with mechanical tension.

Authors:  Peter Engerer; Stephan J Sigrist
Journal:  HFSP J       Date:  2009-12-10

2.  Mechanical tension contributes to clustering of neurotransmitter vesicles at presynaptic terminals.

Authors:  Scott Siechen; Shengyuan Yang; Akira Chiba; Taher Saif
Journal:  Proc Natl Acad Sci U S A       Date:  2009-07-20       Impact factor: 11.205

3.  MEMS Sensors and Microsystems for Cell Mechanobiology.

Authors:  Jagannathan Rajagopalan; M Taher A Saif
Journal:  J Micromech Microeng       Date:  2011-03       Impact factor: 1.881

4.  Elliptical adhesive contact under biaxial stretching.

Authors:  I Argatov; A Papangelo; M Ciavarella
Journal:  Proc Math Phys Eng Sci       Date:  2020-01-29       Impact factor: 2.704

5.  Integrated strain array for cellular mechanobiology studies.

Authors:  C S Simmons; J Y Sim; P Baechtold; A Gonzalez; C Chung; N Borghi; B L Pruitt
Journal:  J Micromech Microeng       Date:  2011-05       Impact factor: 1.881

6.  MEMS Electrostatic Actuation in Conducting Biological Media.

Authors:  Vikram Mukundan; Beth L Pruitt
Journal:  J Microelectromech Syst       Date:  2009-04-01       Impact factor: 2.417

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.