Literature DB >> 1577582

Cavitron Ultrasonic Surgical Aspirator (CUSA) in liver resection.

F Fasulo1, A Giori, S Fissi, F Bozzetti, R Doci, L Gennari.   

Abstract

At the Istituto Nazionale Tumori of Milan, the Cavitron Ultrasonic Surgical Aspirator (CUSA) was employed to perform hepatic resections in 34 patients with primary or secondary liver tumors. The use of CUSA has proved to be very efficient and safe. In lobectomies and extended lobectomies average bleeding was 685 cc with a mean resection time of 28 minutes. In segmentectomies, average bleeding was 540 cc with a mean resection time of 22 minutes. Comparing these data with those we previously obtained in hepatic resections using traditional methods (digitoclasia), it appears that despite overall operative times suffering no significant variation, a considerable reduction in bleeding was obtained, together with a notable fall in post-operative complications.

Entities:  

Mesh:

Year:  1992        PMID: 1577582

Source DB:  PubMed          Journal:  Int Surg        ISSN: 0020-8868


  15 in total

1.  Extra-Glissonian approach in liver resection.

Authors:  Marco Giordano; Santiago Lopez-Ben; Antoni Codina-Barreras; Berta Pardina; Laia Falgueras; Silvia Torres-Bahi; Maite Albiol; Ernest Castro; Joan Figueras
Journal:  HPB (Oxford)       Date:  2010-03       Impact factor: 3.647

2.  Integrated blood conservation programme to minimise blood loss and transfusion requirements in hepatic resection.

Authors:  A Serrablo; J A García-Erce; S Rasal; M Muñoz Gómez
Journal:  HPB (Oxford)       Date:  2002       Impact factor: 3.647

3.  Hemi-hepatectomy in pediatric patients using two-surgeon technique and a liver hanging maneuver.

Authors:  Kyoko Mochizuki; Susumu Eguchi; Ryuichiro Hirose; Taiichiro Kosaka; Mitsuhisa Takatsuki; Takashi Kanematsu
Journal:  World J Gastroenterol       Date:  2011-03-14       Impact factor: 5.742

4.  Hemostasis of the liver, spleen, and bone achieved by electrocautery greased with lidocaine gel.

Authors:  Andy Petroianu
Journal:  Surg Today       Date:  2011-01-26       Impact factor: 2.549

5.  The Cavitron ultrasonic surgical aspirator with a low amplitude is a useful dissection device for surgical procedures: application to vascular detachment and lymph node dissection.

Authors:  Akira Mitsuyoshi; Kenta Inoguchi; Daiju Yokoyama
Journal:  Updates Surg       Date:  2016-03-22

6.  Practical usefulness of ultrasonic surgical aspirator with argon beam coagulation for hepatic parenchymal transection.

Authors:  Yasuhiko Nagano; Kenichi Matsuo; Chikara Kunisaki; Hideyuki Ike; Toshio Imada; Kuniya Tanaka; Shinji Togo; Hiroshi Shimada
Journal:  World J Surg       Date:  2005-07       Impact factor: 3.352

Review 7.  Liver surgery in cirrhosis and portal hypertension.

Authors:  Christina Hackl; Hans J Schlitt; Philipp Renner; Sven A Lang
Journal:  World J Gastroenterol       Date:  2016-03-07       Impact factor: 5.742

8.  Combined portal vein resection for hilar cholangiocarcinoma: a meta-analysis of comparative studies.

Authors:  Xiang-Song Wu; Ping Dong; Jun Gu; Mao-Lan Li; Wen-Guang Wu; Jian-Hua Lu; Jia-Sheng Mu; Qi-Chen Ding; Lin Zhang; Qian Ding; Hao Weng; Ying-Bin Liu
Journal:  J Gastrointest Surg       Date:  2013-04-17       Impact factor: 3.452

9.  The effects of surgical margin and edge cryotherapy after liver resection for colorectal cancer metastases.

Authors:  Rosa M Hou; Francis Chu; Jing Zhao; David L Morris
Journal:  HPB (Oxford)       Date:  2007       Impact factor: 3.647

10.  Water-jet dissection for parenchymal division during hepatectomy.

Authors:  Charles M Vollmer; Elijah Dixon; Ajay Sahajpal; Mark S Cattral; David R Grant; Steven Gallinger; Bryce R Taylor; Paul D Greig
Journal:  HPB (Oxford)       Date:  2006       Impact factor: 3.647

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.