Literature DB >> 15774590

Three-dimensional anal endosonography may improve diagnostic confidence of detecting damage to the anal sphincter complex.

A F Christensen1, B Nyhuus, M B Nielsen, H Christensen.   

Abstract

The aim of study was to investigate the differences between three-dimensional (3D) endosonography and two-dimensional (2D) endosonography in visualizing damage to the anal sphincter complex. 33 patients with a history of damage to the anal sphincters were examined with a 10 MHz rotating endoprobe. Cross-sectional images of the anal sphincters were stored on a 3D system during retraction of the endoprobe through the anal canal. Cross-sectional images (2D) were compared with reconstructed projections (3D) according to five parameters relating to damage of different parts of the sphincter muscles as well as scar-tissue formation in the rectovaginal septum. Depending on whether the investigator felt confident in diagnosis of scar tissue being present or not a numerical value of 1 or 0 was assigned. In this way a scale from 0 to 5 points was achieved, which ideally should be identical in 3D and 2D. Overall both observers felt diagnostic confidence in a median of five parameters (range 4-5) using 3D, compared with a median of four parameters (range 3-5) using 2D (p=0.001). When only assessing the four parameters relating to damage of different parts of the sphincter-muscles the observers felt diagnostic confidence in eight more cases using 3D than 2D. This difference did not reach statistical significance. The overall agreement between the two observers comparing all five parameters was 98.2% using 3D and 87.9% using 2D. 3D anal endosonography improves diagnostic confidence in detecting damage to the anal sphincter complex. The agreement between the two observers was acceptable using 2D but better when using 3D. The 3D method may improve the selection of patients for surgical repair of the anal sphincter complex.

Entities:  

Mesh:

Year:  2005        PMID: 15774590     DOI: 10.1259/bjr/72038963

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  5 in total

1.  Anal sphincter complex: 2D and 3D endoanal and translabial ultrasound measurement variation in normal postpartum measurements.

Authors:  Kate V Meriwether; Rebecca J Hall; Lawrence M Leeman; Laura Migliaccio; Clifford Qualls; Rebecca G Rogers
Journal:  Int Urogynecol J       Date:  2014-10-25       Impact factor: 2.894

Review 2.  Imaging in urogynaecology.

Authors:  Alexandros Derpapas; Giuseppe Alessandro Digesu; Ruwan Fernando; Vik Khullar
Journal:  Int Urogynecol J       Date:  2011-05-28       Impact factor: 2.894

3.  Endoanal ultrasonography in fecal incontinence: Current and future perspectives.

Authors:  Andreia Albuquerque
Journal:  World J Gastrointest Endosc       Date:  2015-06-10

4.  Effects of age and gender on three-dimensional endoanal ultrasonography measurements: development of normal ranges.

Authors:  A M Knowles; C H Knowles; S M Scott; P J Lunniss
Journal:  Tech Coloproctol       Date:  2008-11-18       Impact factor: 3.781

5.  Correlation of three dimensional anorectal manometry and three dimensional endoanal ultrasound findings in primi gravida: a cross sectional study.

Authors:  Dakshitha Praneeth Wickramasinghe; Chamila Sudarshi Perera; Hemantha Senanayake; Dharmabandhu Nandadeva Samarasekera
Journal:  BMC Res Notes       Date:  2015-08-29
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.