Literature DB >> 15773621

Modality-integrated magnetic catheter tracking for x-ray vascular interventions.

Sascha Krueger1, Holger Timinger, Ruediger Grewer, Joern Borgert.   

Abstract

A novel setup for the integration of a magnetic tracking system (MTS) into a catheter laboratory environment by attaching the field generator of the MTS to the C-arm of the x-ray system was investigated. The metal interference of the x-ray system with the MTS then becomes static and can be calibrated. The registration of a tracked catheter to 2D live x-ray images with high and well-defined accuracy is thus possible for arbitrary C-arm positions. Interference with imaging by blocking the field of view is avoided. Real-time registration methods to maintain the registration of the catheter also to static 2D or 3D images (roadmaps), regardless of the C-arm rotation during catheter tracking, were investigated. Residual registration errors of the tracked catheter with respect to the static roadmaps (2D and 3D) were reduced by using the vessel geometry and shape information. The algorithms potentially allow for motion correction (e.g. due to respiration). Using the shape-based correction algorithms the average registration accuracies to static roadmaps for different C-arm angulations and catheter positions were determined to be 3.3-4.2 mm. The magnetic registration of the C-arm was furthermore allowed to compute the imaging geometry (position of the C-arm) and to produce virtual angiographic preview images before contrast injection and x-ray dose application. Thus, optimal projection geometries and collimator settings for the target region can be chosen in an 'off line' fashion. The proposed MTS-supported navigation setup on both 3D (static) and 2D (live and static) roadmaps merges the high resolution and real-time feedback of 2D x-ray images with the navigation support from 3D static images.

Mesh:

Year:  2005        PMID: 15773621     DOI: 10.1088/0031-9155/50/4/002

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  3 in total

1.  Electromagnetic tracking for thermal ablation and biopsy guidance: clinical evaluation of spatial accuracy.

Authors:  Jochen Krücker; Sheng Xu; Neil Glossop; Anand Viswanathan; Jörn Borgert; Heinrich Schulz; Bradford J Wood
Journal:  J Vasc Interv Radiol       Date:  2007-09       Impact factor: 3.464

2.  Multi-Operational Selective Computer-Assisted Targeting of hepatocellular carcinoma-Evaluation of a novel approach for navigated tumor ablation.

Authors:  Pascale Tinguely; Marius Schwalbe; Torsten Fuss; Dominik P Guensch; Andreas Kohler; Iris Baumgartner; Stefan Weber; Daniel Candinas
Journal:  PLoS One       Date:  2018-05-23       Impact factor: 3.240

3.  Localization accuracy of multiple magnets in a myokinetic control interface.

Authors:  Marta Gherardini; Francesco Clemente; Stefano Milici; Christian Cipriani
Journal:  Sci Rep       Date:  2021-03-01       Impact factor: 4.996