Literature DB >> 15771924

New cut-off values of cardiac markers for risk stratification of angina pectoris.

Nelly Jordanova1, Mariann Gyöngyösi, Aliasghar Khorsand, Christine Falkensammer, Gerlinde Zorn, Johann Wojta, Anahit Anvari, Kurt Huber.   

Abstract

BACKGROUND: The aim of this present prospective study was to investigate the accuracy of cardiac markers for the prediction of subsequent cardiac events (cardiac death, acute myocardial infarction and recurrent ischemia requiring coronary revascularization).
METHODS: Fibrinogen, cardiac troponin T, troponin I, creatine phosphokinase myocardial fraction, C-reactive protein and myoglobin at baseline and after 6 h were measured on 154 patients (109 male, 63+/-11 years) with chest pain. Receiver operator characteristic analyses were performed to determine cut-off points of cardiac markers in prediction of adverse events.
RESULTS: The following cut-off values for prediction of cardiac events were calculated: troponin I at baseline 0.3 ng/ml (predictive accuracy=0.870), troponin I at 6 h 0.50 ng/ml (p.a.=0.909); troponin T at baseline 0.05 ng/ml (p.a.=0.643), troponin T at 6 h 0.05 ng/ml (p.a.=0.612), creatine phosphokinase myocardial fraction at baseline 2.0 ng/ml (p.a.=0.721), creatine phosphokinase myocardial fraction at 6 h 2.5 ng/ml (p.a.=0.734), myoglobin at baseline 23 ng/ml (p.a.=0.623), myoglobin at 6 h 26 ng/ml (p.a.=0.617), C-reactive protein at baseline 0.31 mg/dl (p.a.=0.662), C-reactive protein at 6 h 0.55 mg/dl (p.a.=0.682), and fibrinogen at baseline 360 mg/dl (p.a.=0.701). The combination of baseline troponin I with different parameters resulted in a higher sensitivity of up to 98%, with a similar predictive accuracy, but a lower specificity. Additive measurements of cardiac troponin I at 6 h to baseline cardiac troponin T and I proved to be the best combination for prediction of subsequent cardiac events.
CONCLUSIONS: Changes in cut-off levels of cardiac markers and inflammatory parameters results in a high accuracy of risk stratification in patients with chest pains. Combination of these measurements might further help in the identification of patients who would benefit from early coronary revascularization.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15771924     DOI: 10.1016/j.ijcard.2004.03.003

Source DB:  PubMed          Journal:  Int J Cardiol        ISSN: 0167-5273            Impact factor:   4.164


  6 in total

1.  Increase in cardiac myosin binding protein-C plasma levels is a sensitive and cardiac-specific biomarker of myocardial infarction.

Authors:  Suresh Govindan; Diederik Wd Kuster; Brian Lin; Daniel J Kahn; Walter P Jeske; Jeanine M Walenga; Fred Leya; Debra Hoppensteadt; Jawed Fareed; Sakthivel Sadayappan
Journal:  Am J Cardiovasc Dis       Date:  2013-06-10

2.  Diagnostic role of postmortem CK-MB in cardiac death: a systematic review and meta-analysis.

Authors:  Chengyang Xu; Tianyi Zhang; Baoli Zhu; Zhipeng Cao
Journal:  Forensic Sci Med Pathol       Date:  2020-03-19       Impact factor: 2.007

3.  Troponin T elevation and prognosis after multivessel compared with single-vessel elective percutaneous coronary intervention.

Authors:  M B Nienhuis; J P Ottervanger; J-H E Dambrink; L D Dikkeschei; H Suryapranata; A W J van 't Hof; J C A Hoorntje; M J de Boer; A T M Gosselink; F Zijlstra
Journal:  Neth Heart J       Date:  2007-05       Impact factor: 2.380

4.  Prediction of clinical outcome in patients with non-ST-elevation acute coronary syndrome (NSTE-ACS) using the TIMI risk score extended by N-terminal pro-brain natriuretic peptide levels.

Authors:  Rudolf Jarai; Nelly Iordanova; Robert Jarai; Ferenc Jarai; Annamaria Raffetseder; Wolfgang Woloszczuk; Mariann Gyöngyösi; Georg Geyer; Johann Wojta; Kurt Huber
Journal:  Wien Klin Wochenschr       Date:  2007       Impact factor: 1.704

Review 5.  Evaluation of Molecularly Imprinted Polymers for Point-of-Care Testing for Cardiovascular Disease.

Authors:  Brian Regan; Fiona Boyle; Richard O'Kennedy; David Collins
Journal:  Sensors (Basel)       Date:  2019-08-09       Impact factor: 3.576

6.  A smartphone-assisted pressure-measuring-based diagnosis system for acute myocardial infarction diagnosis.

Authors:  Guolin Hong; Gang Rui; Dongdong Zhang; Mingjian Lian; Yuanyuan Yang; Ping Chen; Huijing Yang; Zhichao Guan; Wei Chen; Yan Wang
Journal:  Int J Nanomedicine       Date:  2019-04-08
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.