Literature DB >> 15771278

Vortex shaped current sources in a physical torso phantom.

Mario Liehr1, Jens Haueisen, Matthias Goernig, Paul Seidel, Jukka Nenonen, Toivo Katila.   

Abstract

Recent studies reported differential information in human magnetocardiogram and in electrocardiogram. Vortex currents have been discussed as a possible source of this divergence. With the help of physical phantom experiments, we quantified the influence of active vortex currents on the strength of electric and magnetic signals, and we tested the ability of standard source localization algorithms to reconstruct vortex currents. The active vortex currents were modeled by a set of twelve single current dipoles arranged in a circle and mounted inside a phantom that resembles a human torso. Magnetic and electric data were recorded simultaneously while the dipoles were switched on stepwise one after the other. The magnetic signal strength increased continuously for an increasing number of dipoles switched on. The electric signal strength increased up to a semicircle and decreased thereafter. Source reconstruction with unconstrained focal source models performed well for a single dipole only (less than 3-mm localization error). Minimum norm source reconstruction yielded reasonable results only for a few of the dipole configurations. In conclusion active vortex currents might explain, at least in part, the difference between magnetically and electrically acquired data, but improved source models are required for their reconstruction.

Entities:  

Mesh:

Year:  2005        PMID: 15771278     DOI: 10.1007/s10439-005-8983-6

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  3 in total

1.  Optical multichannel room temperature magnetic field imaging system for clinical application.

Authors:  G Lembke; S N Erné; H Nowak; B Menhorn; A Pasquarelli
Journal:  Biomed Opt Express       Date:  2014-02-25       Impact factor: 3.732

2.  Early Myocardial Repolarization Heterogeneity Is Detected by Magnetocardiography in Diabetic Patients with Cardiovascular Risk Factors.

Authors:  Yi-Cheng Chang; Chau-Chung Wu; Chih-Hung Lin; Yen-Wen Wu; Ying-Chieh Yang; Tien-Jyun Chang; Yi-Der Jiang; Lee-Ming Chuang
Journal:  PLoS One       Date:  2015-07-17       Impact factor: 3.240

3.  Identification of malignant early repolarization pattern by late QRS activity in high-resolution magnetocardiography.

Authors:  Naotsugu Iwakami; Takeshi Aiba; Shiro Kamakura; Hiroshi Takaki; Toshiaki A Furukawa; Tosiya Sato; Wenxu Sun; Toshiaki Shishido; Kunihiro Nishimura; Yuko Yamada-Inoue; Satoshi Nagase; Wataru Shimizu; Satoshi Yasuda; Masaru Sugimachi; Kengo Kusano
Journal:  Ann Noninvasive Electrocardiol       Date:  2020-01-19       Impact factor: 1.468

  3 in total