Literature DB >> 15769696

Port-access aortic valve surgery: a technique in evolution.

Grayson H Wheatley1, Syma L Prince, Morley A Herbert, William H Ryan.   

Abstract

BACKGROUND: Innovative minimally invasive surgical techniques have been developed for treating many cardiac diseases. We reviewed our experience with port-access aortic valve replacement (PAVR) surgery.
METHODS: We retrospectively reviewed the charts of patients with aortic valve disease who underwent surgical correction using the Heartport System and minithoracotomy (PAVR) from January 1998 to December 2002 (n = 58) and matched them 1:1 with a cohort of patients who underwent AVR with conventional sternotomy.
RESULTS: No preoperative statistical differences existed between the groups, including age, sex, New York Heart Association class, and ejection fraction. Perioperatively, there was a statistically significant difference between the AVR and PAVR groups with regard to aortic cross-clamp time (74.0 +/- 22.9 minutes versus 92.7 +/- 20.4 minutes, P < .01). Average operative times improved in the PAVR group by almost 83 minutes from the first 10 patients to patients 21 to 31 (P = .05). PAVR patients also averaged shorter stays in the intensive care unit (ICU) (1.5 days less) and hospital (1.8 days less) and were extubated sooner (4.9 hours). Mortality (1/58, 1.7%) and morbidity (reoperation for bleeding, infection, and stroke) were similar for both groups.
CONCLUSIONS: This minimally invasive approach to aortic valve surgery allows patients to be extubated earlier and promotes shorter stays in the ICU and hospital. These data suggest that the PA approach is an attractive alternative for patients requiring aortic valve surgery. There also appears to be a rapid surgeon learning curve.

Entities:  

Mesh:

Year:  2004        PMID: 15769696     DOI: 10.1532/HSF98.20041104

Source DB:  PubMed          Journal:  Heart Surg Forum        ISSN: 1098-3511            Impact factor:   0.676


  3 in total

Review 1.  Limited versus full sternotomy for aortic valve replacement.

Authors:  Bilal H Kirmani; Sion G Jones; S C Malaisrie; Darryl A Chung; Richard Jnn Williams
Journal:  Cochrane Database Syst Rev       Date:  2017-04-10

2.  A comparison of aortic valve replacement via an anterior right minithoracotomy with standard sternotomy: a propensity score analysis of 492 patients.

Authors:  Michael E Bowdish; Dawn S Hui; John D Cleveland; Wendy J Mack; Raina Sinha; Rupesh Ranjan; Robbin G Cohen; Craig J Baker; Mark J Cunningham; Mark L Barr; Vaughn A Starnes
Journal:  Eur J Cardiothorac Surg       Date:  2015-03-06       Impact factor: 4.191

Review 3.  A systematic review of left ventricular cardio-endoscopic surgery.

Authors:  Erdinc Soylu; Emaddin Kidher; Hutan Ashrafian; George Stavridis; Leanne Harling; Thanos Athanasiou
Journal:  J Cardiothorac Surg       Date:  2017-05-25       Impact factor: 1.637

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.