Abstract

PURPOSE: To develop a technique for documenting and quantifying capsule bend formation in pseudophakic eyes, evaluate when the anterior and posterior lens capsules become completely apposed to the optic, and determine how soon a capsule bend is created at the optic edge of an intraocular lens (IOL) after cataract surgery.
SETTING: Medical University of Vienna, Department of Ophthalmology, Vienna, Austria.
METHODS: This prospective study comprised 33 eyes of 33 patients with age-related cataract who were scheduled to have cataract surgery. All eyes had phacoemulsification with implantation of 1 of 3 types of open-loop IOLs: 1-piece acrylic (SA60AT, Alcon), 3-piece acrylic (AcrySof MA60BM, Alcon), or 3-piece silicone (911A, AMO). Each group included 11 eyes. One and 3 days and 1, 2, 3, and 4 weeks after surgery, contact between the lens capsule and IOL optic as well as capsule bend formation were evaluated using optical coherence tomography (OCT). The postoperative times at which the capsule came into contact with the IOL optic and when the capsule bend formed were determined.
RESULTS: One day postoperatively, the mean distance between the anterior capsule and the IOL was 197 microm in the 1-piece acrylic IOL group, 161 microm in the 3-piece acrylic IOL group, and 220 microm in the 3-piece silicone IOL group. The posterior capsule was in contact with the IOL on the same day or earlier than the anterior capsule in 28 patients (85%). Postoperatively, the capsule bend formed at a mean of 10 days in the 1-piece acrylic group, 13 days in the 3-piece acrylic group, and 15 days in the 3-piece silicone group. The short-term reproducibility of the OCT technique was excellent (r = 0.99).
CONCLUSIONS: Optical coherence tomography produced cross-sectional tomograms of capsule-IOL contact in the early postoperative period. There was no significant difference in the time to capsule bend formation between the 3 IOLs. However, capsule bend formation at the optic edge occurred earlier with the 1-piece acrylic IOL than with the 3-piece silicone IOL.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15767154     DOI: 10.1016/j.jcrs.2004.04.057

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  8 in total

1.  [Influence of intraocular lens material and design on the development of posterior capsule opacification].

Authors:  O Nishi
Journal:  Ophthalmologe       Date:  2005-06       Impact factor: 1.059

2.  Macular thickness after uneventful cataract surgery determined by optical coherence tomography.

Authors:  Burkhard von Jagow; Christian Ohrloff; Thomas Kohnen
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2007-07-10       Impact factor: 3.117

3.  Effect of delivery of MMP inhibitors from PDMS as a model IOL material on PCO markers.

Authors:  Diana Morarescu; Judy A West-Mays; Heather D Sheardown
Journal:  Biomaterials       Date:  2009-12-22       Impact factor: 12.479

4.  Three-dimensional assessment of posterior capsule-intraocular lens interaction with and without primary posterior capsulorrhexis: an intraindividual randomized trial.

Authors:  Mengting Yu; Yue Huang; Yingbin Wang; Suzhen Xiao; Xinna Wu; Wenjie Wu
Journal:  Eye (Lond)       Date:  2021-10-23       Impact factor: 4.456

5.  Post-operative capsular opacification: a review.

Authors:  Shetal M Raj; Abhay R Vasavada; S R Kaid Johar; Vaishali A Vasavada; Viraj A Vasavada
Journal:  Int J Biomed Sci       Date:  2007-12

6.  An Optical Section-Assisted In Vivo Rabbit Model for Capsular Bend and Posterior Capsule Opacification Investigation.

Authors:  Pingjun Chang; Lei Lin; Qian Zheng; Fang Yu; Xiaoyu Yu; Yinying Zhao; Xixia Ding; Weigen Zhu; Jin Li; Yun-E Zhao
Journal:  PLoS One       Date:  2016-02-03       Impact factor: 3.240

7.  The Repeatability Assessment of Three-Dimensional Capsule-Intraocular Lens Complex Measurements by Means of High-Speed Swept-Source Optical Coherence Tomography.

Authors:  Xixia Ding; Qinmei Wang; Pingjun Chang; Jin Li; Giacomo Savini; Jinhai Huang; Shenghai Huang; Yinying Zhao; Na Liao; Lei Lin; Xiaoyu Yu; Yun-e Zhao
Journal:  PLoS One       Date:  2015-11-23       Impact factor: 3.240

8.  Assessment of tilt and decentration of crystalline lens and intraocular lens relative to the corneal topographic axis using anterior segment optical coherence tomography.

Authors:  Shuhei Kimura; Yuki Morizane; Yusuke Shiode; Masayuki Hirano; Shinichiro Doi; Shinji Toshima; Atsushi Fujiwara; Fumio Shiraga
Journal:  PLoS One       Date:  2017-09-01       Impact factor: 3.240

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.