Literature DB >> 15766958

Effects of iron surface pretreatment on sorption and reduction kinetics of trichloroethylene in a closed batch system.

Chin Jung Lin1, Shang-Lien Lo.   

Abstract

The decline of trichloroethylene (TCE) in a metallic iron-water system results from the combination of reduction reaction and sorption onto iron surfaces. Sorption, particularly by highly impure iron, accelerates the removal of TCE from the aqueous phase, but delays the prevalence of steady-state conditions. In this case, an overly high value of reaction rate constant in the design of a treatment system would be used. In this work, the effects of an iron surface with 8.0% C, 6.1% O and 0.8% Si separately following HCl-washing and H2-reducing pretreatment on sorption and reduction rates were examined. The amounts of both aqueous and sorbed TCE were measured using a modified solvent-extraction method. TCE sorption onto an iron surface, as quantified by the Langmuir sorption maximum, followed the trend H2-reduced Fe0 > HCl-washed Fe0 > untreated Fe0 (0.887, 0.365 and 0.311 mg/g, respectively). Measurements of the concentration of sorbed TCE revealed that about 34-37% of the initial mass of TCE in the aqueous phase was removed by sorption by H2-reduced Fe0, 16-19% was removed by HCl-washed Fe0 and 13-16% was removed by untreated Fe0. A combination of new and previously reported data on cast iron's capacity to sorb TCE revealed a linear relationship between this capacity and the C fraction in the surface of the iron, with the coefficient of determination (r2) exceeding 0.99. The first-order observed rate constants (k(obs)) of the reduction of TCE in contact with Fe0 were obtained from the slope of a plot of total TCE loss rate (-dC(T)/dt) versus the amount of TCE in the aqueous phase (C(w)) using linear least-squares analysis. The k(obs) values were 0.080, 0.148 and 0.191 h(-1) for untreated, HCl-washed and H2-reduced Fe0, respectively. Normalized to iron surface area concentration, the specific rate constants (k(SA)) were 2.3 7x 10(-3) , 2.31 x 10(-3) and 5.62 x 10(-3) h(-1) m(-2) L, respectively. The results indicated that HCl-washing approximately doubled k(obs), primarily because of the increase in the surface area of the iron, and it slightly decreased k(SA) due to rapid corrosion during the rinsing process. Both the number of reactive sites and the sorption capacity per unit iron surface area through the H2-reducing pretreatment were increased due to the reduction of iron oxide layer and the carbonization of carbon-containing subjects on the iron's surface. Hence, the H2 reduction of cast iron promotes the removal of TCE from contaminated water by the concurrent sorption and reduction.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15766958     DOI: 10.1016/j.watres.2004.06.035

Source DB:  PubMed          Journal:  Water Res        ISSN: 0043-1354            Impact factor:   11.236


  3 in total

1.  Pentachlorophenol dechlorination with zero valent iron: a Raman and GCMS study of the complex role of surficial iron oxides.

Authors:  Buddhika Gunawardana; Peter J Swedlund; Naresh Singhal; Michel K Nieuwoudt
Journal:  Environ Sci Pollut Res Int       Date:  2018-04-20       Impact factor: 4.223

2.  Enhanced removal of chromium(vi) by Fe(iii)-reducing bacterium coated ZVI for wastewater treatment: batch and column experiments.

Authors:  Bin Zheng; Yizi Ye; Baowei Hu; Chunhui Luo; Yuling Zhu
Journal:  RSC Adv       Date:  2019-11-06       Impact factor: 4.036

3.  An insight in magnetic field enhanced zero-valent iron/H2O2 Fenton-like systems: Critical role and evolution of the pristine iron oxides layer.

Authors:  Wei Xiang; Beiping Zhang; Tao Zhou; Xiaohui Wu; Juan Mao
Journal:  Sci Rep       Date:  2016-04-07       Impact factor: 4.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.