Wear of ten dental restorative materials in five wear simulators--results of a round robin test.

S D Heintze1, G Zappini, V Rousson.   

Abstract

OBJECTIVE: The purpose of the present study was to prove the hypothesis that different wear measurement methods generate different material rankings.
METHODS: Ten restorative materials, eight composites (BelleGlass, Chromasit, Estenia, Heliomolar RO, SureFil, Targis cured at 95 and 130 degrees C, Tetric Ceram) an amalgam (Amalcap) and a ceramic (Empress) have been evaluated with regard to the wear with five different wear methods (IVOCLAR, ZURICH, MUNICH, OHSU, ACTA). Every center received specimens, which Ivoclar Vivadent had made using the same batch. The test centers did not know which brand they were testing. After completion of the wear test, the raw data were sent to IVOCLAR for further analysis. The statistical analysis of the data included logarithmic transformation of the data, the calculation of relative ranks of each material within each test center, measures of agreement between methods, the discrimination power and coefficient of variation of each method as well as measures of the consistency and global performance for each material.
RESULTS: Relative ranks of the materials varied tremendously between the test centers. When all materials were taken into account and the test methods compared with each other, only ACTA agreed reasonably well with two other methods, i.e. OHSU and ZURICH. On the other hand, MUNICH did not agree with the other methods at all. The ZURICH method showed the lowest discrimination power, ACTA and IVOCLAR the highest. Materialwise, the best global performance was achieved by Empress, which was clearly ahead of BelleGlass, SureFil and Estenia. In contrast, Heliomolar RO, Tetric Ceram and especially Chromasit demonstrated a poor global performance. The best consistency was achieved by BelleGlass and SureFil, whereas the consistency of Amalcap and Heliomolar RO was poor. SIGNIFICANCE: As the different wear simulator settings measure different wear mechanisms, it seems reasonable to combine at least two different wear settings to assess the wear resistance of a new material.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15766577     DOI: 10.1016/j.dental.2004.05.003

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  11 in total

1.  Comparative study of the wear behavior of composites for posterior restorations.

Authors:  Cecilia P Turssi; Juliana J Faraoni-Romano; Márcio de Menezes; Mônica C Serra
Journal:  J Mater Sci Mater Med       Date:  2007-01       Impact factor: 3.896

2.  An in vitro investigation of wear resistance and hardness of composite resins.

Authors:  Liqun Cao; Xinyi Zhao; Xu Gong; Shouliang Zhao
Journal:  Int J Clin Exp Med       Date:  2013-06-26

3.  Inverse correlations between wear and mechanical properties in biphasic dental materials with ceramic constituents.

Authors:  Oscar Borrero-Lopez; Fernando Guiberteau; Yu Zhang; Brian R Lawn
Journal:  J Mech Behav Biomed Mater       Date:  2020-03-12

4.  In vitro investigation of the performance of different restorative materials under cast circumferential clasps for removable dental prostheses.

Authors:  Peter Pospiech; Florian Nagel; Florian Gebhart; Frank P Nothdurft; Gergo Mitov
Journal:  Clin Oral Investig       Date:  2011-12-17       Impact factor: 3.573

5.  Wear of ceramic-based dental materials.

Authors:  Oscar Borrero-Lopez; Fernando Guiberteau; Yu Zhang; Brian R Lawn
Journal:  J Mech Behav Biomed Mater       Date:  2019-01-12

6.  Characterization of third-body media particles and their effect on in vitro composite wear.

Authors:  Nathaniel C Lawson; Deniz Cakir; Preston Beck; Mark S Litaker; John O Burgess
Journal:  Dent Mater       Date:  2012-05-10       Impact factor: 5.304

7.  Wear of the Charité® lumbar intervertebral disc replacement investigated using an electro-mechanical spine simulator.

Authors:  Parshia Moghadas; Aziza Mahomed; Duncan E T Shepherd; David W L Hukins
Journal:  Proc Inst Mech Eng H       Date:  2015-03       Impact factor: 1.617

8.  Initial sliding wear kinetics of two types of glass ionomer cement: a tribological study.

Authors:  Cyril Villat; Pierre Ponthiaux; Nelly Pradelle-Plasse; Brigitte Grosgogeat; Pierre Colon
Journal:  Biomed Res Int       Date:  2014-06-29       Impact factor: 3.411

9.  Wear of primary teeth caused by opposed all-ceramic or stainless steel crowns.

Authors:  Jae-Won Choi; Ik-Hyun Bae; Tae-Hwan Noh; Sung-Won Ju; Tae-Kyoung Lee; Jin-Soo Ahn; Tae-Sung Jeong; Jung-Bo Huh
Journal:  J Adv Prosthodont       Date:  2016-02-23       Impact factor: 1.904

10.  Methods for quantitative measurement of tooth wear using the area and volume of virtual model cusps.

Authors:  Soo-Hyun Kim; Young-Seok Park; Min-Kyoung Kim; Sulhee Kim; Seung-Pyo Lee
Journal:  J Periodontal Implant Sci       Date:  2018-04-30       Impact factor: 2.614

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.