Observer variability when evaluating patient movement from electronic portal images of pelvic radiotherapy fields.

D Geraint Lewis1, Karen R Ryan, Cyril W Smith.   

Abstract

BACKGROUND AND
PURPOSE: A study has been performed to evaluate inter-observer variability when assessing pelvic patient movement using an electronic portal imaging device (EPID).
MATERIALS AND METHODS: Four patient image sets were used with 3-6 portal images per set. The observer group consisted of nine radiographers with 3-18 months clinical EPID experience. The observers outlined bony landmarks on a digital simulator image and used matching software to evaluate field placement errors (FPEs) on each portal image relative to the reference simulator image. Data were evaluated statistically, using a two-component analysis of variance technique, to quantify both the inter-observer variability in evaluating FPEs and inter-fraction variability in patient position relative to the residuals of the analysis. Intra-observer variability was also estimated using four of the observers carrying out three sets of repeat readings.
RESULTS: Eight sets of variance data were analysed, based on FPEs in two orthogonal directions for each of the four patient image sets studied. Initial analysis showed that both inter-observer variation and inter-fraction-patient position variation were statistically significant (P<0.05) in seven of the eight cases evaluated. The averaged root-mean-square (RMS) deviation of the observers from the group mean was 1.1 mm, with a maximum deviation of 5.0 mm recorded for an individual observer. After additional training and re-testing of two of the observers who recorded the largest deviations from the group mean, a subsequent analysis showed the inter-observer variability for the group to be significant in only three of the eight cases, with averaged RMS deviation reduced to 0.5 mm, with a maximum deviation of 2.7 mm. The intra-observer variability was 0.5 mm, averaged over the four observers tested.
CONCLUSIONS: We have developed a quantitative approach to evaluate inter-observer variability in terms of its statistical significance compared to inter-fraction patient movement. This will assist us in training and assessing observers required to perform this task on a routine basis.

Entities:  

Mesh:

Year:  2004        PMID: 15763308     DOI: 10.1016/j.radonc.2004.11.009

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  4 in total

1.  Prostate positioning using cone-beam computer tomography based on manual soft-tissue registration: interobserver agreement between radiation oncologists and therapists.

Authors:  B A Jereczek-Fossa; C Pobbiati; L Santoro; C Fodor; P Fanti; S Vigorito; G Baroni; D Zerini; O De Cobelli; R Orecchia
Journal:  Strahlenther Onkol       Date:  2013-08-17       Impact factor: 3.621

2.  Consistency in electronic portal imaging registration in prostate cancer radiation treatment verification.

Authors:  Eric Berthelet; Pauline T Truong; Sergei Zavgorodni; Veronika Moravan; Mitchell C Liu; Jim Runkel; Bill Bendorffe; Dorothy Sayers
Journal:  Radiat Oncol       Date:  2006-09-19       Impact factor: 3.481

3.  Impact of abdominal compression on setup error and image matching during radical abdominal radiotherapy.

Authors:  Kwun-Ye Chu; Rosie Cooke; Frank Van den Heuvel; Somnath Mukherjee; Maria A Hawkins
Journal:  Tech Innov Patient Support Radiat Oncol       Date:  2019-12-16

4.  Voluntary breath-holding for breast cancer radiotherapy is consistent and stable.

Authors:  Ruth Colgan; Matthew James; Frederick R Bartlett; Anna M Kirby; Ellen M Donovan
Journal:  Br J Radiol       Date:  2015-08-13       Impact factor: 3.039