Literature DB >> 15762566

Integrated microfluidic device for mass spectrometry-based proteomics and its application to biomarker discovery programs.

Marie-Helene Fortier1, Eric Bonneil, Paul Goodley, Pierre Thibault.   

Abstract

The present investigation describes the analytical performances of a microfluidic device comprising an enrichment column, a reversed-phase separation channel, and a nanoelectrospray emitter embedded altogether in polyimide layers. This configuration minimizes transfer lines and connections and reduces postcolumn peak broadening and dead volumes. This compact and versatile modular nanoLC-chip system was interfaced to both ion trap and time-of-flight mass spectrometers, and its analytical potentials were evaluated in the context of proteomics applications. The figures of merit of this system in terms of peak capacity, reproducibility, sensitivity, and linear dynamic range of peptide detection were determined using tryptic digests of complex protein extracts including albumin- and immunoglobulin-depleted rat plasma samples. The analysis of peak profiles for more than 600 peptide ions reproducibly detected across replicate nanoLC-chip-MS runs (n = 10) indicated that this system provided good reproducibility of retention time and peak intensity with RSD values of less than 0.5 and 9.1%, respectively. Variation in peptide abundance as low as 2-fold changes was identified for spiked tryptic digests present at levels of 2-5 fmol in plasma samples. Sensitivity measurements were performed on dilution series of protein digests spiked into rat plasma samples and provided a detection limit of 1-5 fmol. The modular concept of the microfluidic systems also facilitated the integration of two-dimensional chromatography (strong cation exchange/C18) thereby increasing the sample loading and selectivity of the nanoLC-chip-MS system. The application of this integrated device was evaluated for complex rat plasma samples to compare the number of protein identifications obtained using one- and two-dimensional nanoLC-chip-MS/MS.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15762566     DOI: 10.1021/ac048506d

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  20 in total

1.  Online Peptide fractionation using a multiphasic microfluidic liquid chromatography chip improves reproducibility and detection limits for quantitation in discovery and targeted proteomics.

Authors:  Christoph Krisp; Hao Yang; Remco van Soest; Mark P Molloy
Journal:  Mol Cell Proteomics       Date:  2015-04-07       Impact factor: 5.911

Review 2.  Fast, comprehensive two-dimensional liquid chromatography.

Authors:  Dwight R Stoll; Xiaoping Li; Xiaoli Wang; Peter W Carr; Sarah E G Porter; Sarah C Rutan
Journal:  J Chromatogr A       Date:  2007-08-30       Impact factor: 4.759

3.  Abstracts of papers presented at the 2008 pittsburgh conference.

Authors:  Peter B Stockwell
Journal:  J Autom Methods Manag Chem       Date:  2009-04-05

4.  A negative-pressure-driven microfluidic chip for the rapid detection of a bladder cancer biomarker in urine using bead-based enzyme-linked immunosorbent assay.

Authors:  Yen-Heng Lin; Ying-Ju Chen; Chao-Sung Lai; Yi-Ting Chen; Chien-Lun Chen; Jau-Song Yu; Yu-Sun Chang
Journal:  Biomicrofluidics       Date:  2013-03-07       Impact factor: 2.800

5.  Development and characterization of a novel plug and play liquid chromatography-mass spectrometry (LC-MS) source that automates connections between the capillary trap, column, and emitter.

Authors:  Michael S Bereman; Edward J Hsieh; Thomas N Corso; Colleen K Van Pelt; Michael J Maccoss
Journal:  Mol Cell Proteomics       Date:  2013-02-19       Impact factor: 5.911

6.  Meta-analysis of peptides to detect protein significance.

Authors:  Yuping Zhang; Zhengqing Ouyang; Wei-Jun Qian; Richard D Smith; Wing Hung Wong; Ronald W Davis
Journal:  Stat Interface       Date:  2020-07-31       Impact factor: 0.582

7.  Integrated Microfluidic Reactors.

Authors:  Wei-Yu Lin; Yanju Wang; Shutao Wang; Hsian-Rong Tseng
Journal:  Nano Today       Date:  2009-12       Impact factor: 20.722

8.  Isomer-specific chromatographic profiling yields highly sensitive and specific potential N-glycan biomarkers for epithelial ovarian cancer.

Authors:  Serenus Hua; Cynthia C Williams; Lauren M Dimapasoc; Grace S Ro; Sureyya Ozcan; Suzanne Miyamoto; Carlito B Lebrilla; Hyun Joo An; Gary S Leiserowitz
Journal:  J Chromatogr A       Date:  2013-01-11       Impact factor: 4.759

9.  A preliminary study of metalloproteins in CSF by CapLC-ICPMS and NanoLC-CHIP/ITMS.

Authors:  Jenny Ellis; Estela Del Castillo; Maria Montes Bayon; Rudolf Grimm; Joseph F Clark; Gail Pyne-Geithman; Steve Wilbur; Joseph A Caruso
Journal:  J Proteome Res       Date:  2008-07-29       Impact factor: 4.466

10.  Analytical performance of a venturi-assisted array of micromachined ultrasonic electrosprays coupled to ion trap mass spectrometry for the analysis of peptides and proteins.

Authors:  Christina Y Hampton; Thomas P Forbes; Mark J Varady; J Mark Meacham; Andrei G Fedorov; F Levent Degertekin; Facundo M Fernández
Journal:  Anal Chem       Date:  2007-10-03       Impact factor: 6.986

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.