Literature DB >> 15751384

Bone remodeling in immediately loaded and unloaded titanium dental implants: a histologic and histomorphometric study in humans.

Marco Degidi1, Antonio Scarano, Maurizio Piattelli, Vittoria Perrotti, Adriano Piattelli.   

Abstract

Remodeling is thought to prevent microdamage accumulation caused by repetitive loading and to increase the fatigue life of bone. The bone remodeling rate (BRR) is the period of time needed for new bone to replace the existing bone and to allow for the adaptation of bone to its environment. BRR is expressed as a percentage or volume of new bone within a specific time period. The aim of the present study was to evaluate bone remodeling events on submerged and immediately loaded dental implants. Twelve patients with edentulous mandibles participated in this study. All patients were rehabilitated with fixed mandibular prostheses, with 10 dental implants per patient. An additional implant was inserted in the most distal posterior mandibular jaw region. In 6 patients, these additional implants were loaded with a fixed provisional prosthesis the same day of the implant surgery and loaded. In the other 6 patients, the additional implants were left submerged and not loaded. After 6 months, all the additional implants were retrieved with a trephine. The percentage of woven and lamellar bone, number of osteoclasts and osteoblasts, and percentage of bone labeled by tetracycline at 0.5 mm and 2 mm from the implant surface were evaluated. The percentage of lamellar bone, number of osteoblasts, and percentage of bone tetracycline labeling was significantly higher in the loaded implants than in the unloaded implants (P =.0001). Also in the loaded implants, the percentage of woven and lamellar bone, number of osteoclasts and osteoblasts, and percentage of bone tetracycline labeling was significantly higher at 0.5 mm than at 2 mm from the implant surface (P =.0001). No such differences were found in unloaded implants (P =.377). In conclusion, we found that (1) loading appeared to stimulate bone remodeling at the interface, (2) a higher percentage of lamellar bone was found in loaded implants, (3) the percentage of bone labeling was higher at the interface of loaded implants, (4) no differences were found in the BRRs between immediately loaded and unloaded implants, and (5) immediate loading had not interfered on the lamellar bone formation at the interface and had not produced formation of woven bone at the interface.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15751384     DOI: 10.1563/0-717.1

Source DB:  PubMed          Journal:  J Oral Implantol        ISSN: 0160-6972            Impact factor:   1.779


  8 in total

1.  Characterization of eight different tetracyclines: advances in fluorescence bone labeling.

Authors:  Christoph Pautke; Stephan Vogt; Kilian Kreutzer; Cornelia Haczek; Gabriele Wexel; Andreas Kolk; Andreas B Imhoff; Horst Zitzelsberger; Stefan Milz; Thomas Tischer
Journal:  J Anat       Date:  2010-04-26       Impact factor: 2.610

2.  Survival of Implants in Immediate Extraction Sockets of Anterior Teeth: Early Clinical Results.

Authors:  Mohammad Sabir; Mohammad Nazish Alam
Journal:  J Clin Diagn Res       Date:  2015-06-01

3.  Peri-implant bone tissues around retrieved human implants after time periods longer than 5 years: a retrospective histologic and histomorphometric evaluation of 8 cases.

Authors:  Giovanna Iezzi; Adriano Piattelli; Carlo Mangano; Jamil A Shibli; Giovanni Vantaggiato; Massimo Frosecchi; Claudio Di Chiara; Vittoria Perrotti
Journal:  Odontology       Date:  2012-08-28       Impact factor: 2.634

4.  Influence of late removal after treatment on the removal torque of microimplants.

Authors:  Ho-Jin Kim; Hyo-Sang Park
Journal:  Korean J Orthod       Date:  2022-05-25       Impact factor: 1.361

5.  Application of Orthodontic Immediate Force on Dental Implants: Histomorphologic and Histomorphometric Assessment.

Authors:  Mansour Rismanchian; Sayed Hamid Raji; Sayed Mohammad Razavi; Danesh Teimouri Rick; Amin Davoudi
Journal:  Ann Maxillofac Surg       Date:  2017 Jan-Jun

6.  An ectodermal dysplasia patient treated with a small diameter implant supporting a single crown.

Authors:  Andrea Mascolo; Elio Boschetti; Dennis Flanagan
Journal:  Clin Cosmet Investig Dent       Date:  2018-08-10

7.  Jawbone remodeling: a conceptual study based on Synchrotron High-resolution Tomography.

Authors:  Giovanna Iezzi; Carlo Mangano; Antonio Barone; Federico Tirone; Luigi Baggi; Giuliana Tromba; Adriano Piattelli; Alessandra Giuliani
Journal:  Sci Rep       Date:  2020-03-02       Impact factor: 4.379

8.  Comparative evaluation of two types of immediately loaded implants using biomechanical and histomorphometric tests: an animal case study.

Authors:  Mansour Rismanchian; Bijan Movahedian; Navid Khalighinejad; Hamid Badrian; Sayed Mohammad Razavi; Afsaneh Nekouie
Journal:  ISRN Dent       Date:  2012-07-18
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.