Literature DB >> 15749004

Impact of setup uncertainty in the dosimetry of prostate and surrounding tissues in prostate cancer patients treated with Peacock/IMRT.

Salahuddin Ahmad1, Maria T Vlachaki, Terrance N Teslow, Chad M Amosson, John McGary, Bin S Teh, Shiao Y Woo, E Brian Butler, Walter H Grant.   

Abstract

The purpose of this paper was to assess the effect of setup uncertainty on dosimetry of prostate, seminal vesicles, bladder, rectum, and colon in prostate cancer patients treated with Peacock intensity-modulated radiation therapy (IMRT). Ten patients underwent computed tomography (CT) scans using the "prostate box" for external, and an "endorectal balloon" for target immobilization devices, and treatment plans were generated (T1). A maximum of +/-5-mm setup error was chosen to model dosimetric effects. Isodose lines from the T1 treatment plan were then superimposed on each patient's CT anatomy shifted by 5 mm toward the cephalad and caudal direction, generating 2 more dosimetric plans (H1 and H2, respectively). Average mean doses ranged from 74.5 to 74.92 Gy for prostate and 73.65 to 74.94 Gy for seminal vesicles. Average percent target volume below 70 Gy increased significantly for seminal vesicles, from 0.53% to 6.26%, but minimally for prostate, from 2.08% to 4.4%. Dose statistics adhered to prescription limits for normal tissues. Setup uncertainty had minimum impact on target dose escalation and normal tissue dosing. The impact of target dose inhomogeneity is currently evaluated in clinical studies.

Entities:  

Mesh:

Year:  2005        PMID: 15749004     DOI: 10.1016/j.meddos.2004.10.001

Source DB:  PubMed          Journal:  Med Dosim        ISSN: 1873-4022            Impact factor:   1.482


  3 in total

1.  A simulation technique for computation of the dosimetric effects of setup, organ motion and delineation uncertainties in radiotherapy.

Authors:  Bongile Mzenda; Mir Hosseini-Ashrafi; Antony Palmer; Honghai Liu; David J Brown
Journal:  Med Biol Eng Comput       Date:  2010-04-23       Impact factor: 2.602

2.  Phase II study of accelerated Linac-based SBRT in five consecutive fractions for localized prostate cancer.

Authors:  Filippo Alongi; Rosario Mazzola; Alba Fiorentino; Stefanie Corradini; Dario Aiello; Vanessa Figlia; Fabiana Gregucci; Riccardo Ballario; Stefano Cavalleri; Ruggero Ruggieri
Journal:  Strahlenther Onkol       Date:  2018-07-12       Impact factor: 3.621

3.  Effects of error on dose of target region and organs at risk in treating nasopharynx cancer with intensity modulated radiation therapy.

Authors:  Guangsheng Liu; Sumei Zhang; Yuzhuo Ma; Qingyuan Wang; Xingxiu Chen; Lingling Zhang; Fengmei Ma
Journal:  Pak J Med Sci       Date:  2016 Jan-Feb       Impact factor: 1.088

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.