Literature DB >> 15745774

Interim results of the United States investigational device study of the Ophtec capsular tension ring.

Francis W Price1, Richard J Mackool, Kevin M Miller, Paul Koch, Thomas A Oetting, A Tim Johnson.   

Abstract

PURPOSE: To evaluate the safety and efficacy of the Ophtec capsular tension ring (CTR) in providing capsular support during and/or after cataract extraction in cases of a weak or partially broken ciliary zonule.
DESIGN: Phase III multicenter, nonrandomized, investigational device study. PARTICIPANTS: Twelve investigators at 9 sites enrolled 224 subjects and placed 255 CTRs.
METHODS: Capsular tension rings were placed in patients who were found to have a weakened or partially broken ciliary zonule comprising <34% of the circumference of the lens capsule. Two CTR models were evaluated, with noncompressed diameters of 12 mm and 13 mm. Patients were examined preoperatively, intraoperatively, and postoperatively at day 1 and months 1, 3, 6, and 12. MAIN OUTCOME MEASURES: Rate of successful stabilization of the capsular bag and intraocular lens (IOL) centration, complications, and adverse events.
RESULTS: Interim results from this ongoing study indicate that immediately after surgery 98.8% of IOLs were centered and 1.2% of the IOLs implanted (3/251) were not centered. Subsequently, the prevalence of decentered IOLs was 1.7% (4/236) 3 months after surgery, 3.8% (8/211) 6 months after surgery, and 2.3% (4/172) 12 months after surgery. The primary complication was posterior capsular opacification, which is unlikely to be a complication of CTR insertion. Neodymium:yttrium-aluminum-garnet laser capsulotomies have been performed in 12.8% of eyes by 12 months (22/172).
CONCLUSIONS: Ophtec CTR models 275 and 276 safely provided capsular support during and after cataract surgery in cases where the zonule was weak or partially broken.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15745774     DOI: 10.1016/j.ophtha.2004.09.022

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  5 in total

1.  Iris retractors: the saviours in cataract surgery for cataract in lens coloboma.

Authors:  Alok Sati; Sandeep Shankar; V S Gurunadh; Virender S Sangwan
Journal:  BMJ Case Rep       Date:  2013-12-17

2.  Capsular tension ring implantation after lens extraction for management of subluxated cataracts.

Authors:  Xiao Ma; Zhaohui Li
Journal:  Int J Clin Exp Pathol       Date:  2014-06-15

3.  Effect of a capsular tension ring on prevention of intraocular lens decentration and tilt and on anterior capsule contraction after cataract surgery.

Authors:  Minehiro Takimoto; Ken Hayashi; Hideyuki Hayashi
Journal:  Jpn J Ophthalmol       Date:  2008-11-11       Impact factor: 2.447

Review 4.  Cataract surgery in patients with pseudoex-foliation syndrome: current updates.

Authors:  Luigi Fontana; Marco Coassin; Alfonso Iovieno; Antonio Moramarco; Luca Cimino
Journal:  Clin Ophthalmol       Date:  2017-07-31

5.  Anterior Capsule Opening Contraction and Late Intraocular Lens Dislocation after Cataract Surgery in Patients with Weak or Partially Absent Zonular Support.

Authors:  Juris Vanags; Renārs Erts; Guna Laganovska
Journal:  Medicina (Kaunas)       Date:  2021-01-03       Impact factor: 2.430

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.