Literature DB >> 15744840

Engineering hepatocellular morphogenesis and function via ligand-presenting hydrogels with graded mechanical compliance.

Eric J Semler1, Perry A Lancin, Anouska Dasgupta, Prabhas V Moghe.   

Abstract

In order to evaluate the sensitivity of hepatocellular cultures to variations in both substrate stiffness and bioactive ligand presentation, hepatocytes were cultured on differentially compliant polyacrylamide gel discs functionalized with varying amounts of the ECM ligand, fibronectin (FN). Subconfluent cell cultures were established in a multiwell plate format enabling the systematic evaluation of cellular response to both underlying substrate rigidity and substrate ligand concentration. Hepatocellular morphogenesis, regulated by a combination of both ligand density and substrate compliance, resulted in a broad spectrum of patterns of cellular reorganization and assembly ranging from highly two-dimensionally spread cells to highly compact, three-dimensional spheroids. Cell compaction was promoted by increasing levels of substrate mechanical compliance and generally inhibited by increasing concentrations of substrate-bound FN. We identified regimes of substrate compliance in which cells are highly responsive or relatively insensitive to the level of substrate-based ligands. For example, while FN presentation did not have a large impact on cell morphogenesis for cultures on highly compliant gels (G' = 1.9 kPa), hepatocytes on "firm" substrates of intermediate compliance (G' = 5.6 kPa) exhibited approximately a 2-fold increase in cell area between the highest and lowest FN concentrations used in this study. Further, we show that increasing substrate compliance at constant ligand concentration results in increased levels of liver-specific albumin secretion while increasing levels of FN at constant substrate rigidity yield reduced liver-specific functional activity. These substrate-elicited differences in cell function also coincided with analogous changes in the transcript levels of metabolic, growth-related, and liver-specific gene markers. Notably, these results also demonstrated that "firm" gel substrates elicit the most hepatocyte functional sensitivity to substrate-based FN presentation. Overall, our findings indicate that hepatocellular responsiveness to ligand concentration can be acutely regulated by gradation of substrate compliance, suggesting that concerted biochemical and biophysical design strategies may be critical toward the fabrication of hepatospecific biomaterials that effectively support desired levels of liver-specific function. 2004 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15744840     DOI: 10.1002/bit.20328

Source DB:  PubMed          Journal:  Biotechnol Bioeng        ISSN: 0006-3592            Impact factor:   4.530


  25 in total

Review 1.  The applications of atomic force microscopy to vision science.

Authors:  Julie A Last; Paul Russell; Paul F Nealey; Christopher J Murphy
Journal:  Invest Ophthalmol Vis Sci       Date:  2010-12       Impact factor: 4.799

2.  Characterizing the effects of heparin gel stiffness on function of primary hepatocytes.

Authors:  Jungmok You; Su-A Park; Dong-Sik Shin; Dipali Patel; Vijay Krishna Raghunathan; Mihye Kim; Christopher J Murphy; Giyoong Tae; Alexander Revzin
Journal:  Tissue Eng Part A       Date:  2013-08-16       Impact factor: 3.845

3.  Biomaterials for liver tissue engineering.

Authors:  Era Jain; Apeksha Damania; Ashok Kumar
Journal:  Hepatol Int       Date:  2013-12-27       Impact factor: 6.047

4.  Multiwell stiffness assay for the study of cell responsiveness to cytotoxic drugs.

Authors:  Silviya Zustiak; Ralph Nossal; Dan L Sackett
Journal:  Biotechnol Bioeng       Date:  2013-09-06       Impact factor: 4.530

Review 5.  A hitchhiker's guide to mechanobiology.

Authors:  Jeroen Eyckmans; Thomas Boudou; Xiang Yu; Christopher S Chen
Journal:  Dev Cell       Date:  2011-07-19       Impact factor: 12.270

6.  Elastic modulus determination of normal and glaucomatous human trabecular meshwork.

Authors:  Julie A Last; Tingrui Pan; Yuzhe Ding; Christopher M Reilly; Kate Keller; Ted S Acott; Michael P Fautsch; Christopher J Murphy; Paul Russell
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-04-05       Impact factor: 4.799

7.  Simple polyacrylamide-based multiwell stiffness assay for the study of stiffness-dependent cell responses.

Authors:  Sana Syed; Amin Karadaghy; Silviya Zustiak
Journal:  J Vis Exp       Date:  2015-03-25       Impact factor: 1.355

8.  Substrate stiffness regulates primary hepatocyte functions.

Authors:  Vaishaali Natarajan; Eric J Berglund; Dorothy X Chen; Srivatsan Kidambi
Journal:  RSC Adv       Date:  2015-09-14       Impact factor: 3.361

9.  Fibronectin in aging extracellular matrix fibrils is progressively unfolded by cells and elicits an enhanced rigidity response.

Authors:  Meher Antia; Gretchen Baneyx; Kristopher E Kubow; Viola Vogel
Journal:  Faraday Discuss       Date:  2008       Impact factor: 4.008

10.  Modulation of hepatocyte phenotype in vitro via chemomechanical tuning of polyelectrolyte multilayers.

Authors:  Alice A Chen; Salman R Khetani; Sunyoung Lee; Sangeeta N Bhatia; Krystyn J Van Vliet
Journal:  Biomaterials       Date:  2008-11-28       Impact factor: 12.479

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.