Robust design of finger probe in non-invasive total haemoglobin monitor.

G Yoon1, S J Kim, K J Jeon.   

Abstract

The development of a non-invasive monitor of total haemoglobin has been reported previously. The paper presents the design and testing of a finger probe used in that optical haemoglobin monitor. When a finger is inserted into the probe, light is radiated onto the nail, and a silicon detector measures transmitted light. This finger probe can have different values or settings for design parameters such as the internal colour, detector area, the emission area of a light source and the distance between the light source and detector. Design of experiment (DOE) was introduced to select the best combination of design parameters that were robust to external conditions such as finger alignment and ambient light. An optimally designed finger probe from DOE analysis, compared with the initial design, increased the correlation coefficient from 0.696 to 0.869 and improved the standard deviation from 1.18 to 0.81 g dl(-1) in predicting total haemoglobin. This was under different conditions of finger-probe alignment. Under different ambient light conditions, the optimum design improved the correlation coefficient from 0.735 to 0.870 and reduced the standard deviation from 1.14 to 0.83 g dl(-1).

Mesh:

Year:  2005        PMID: 15742729     DOI: 10.1007/bf02345132

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  4 in total

1.  Noninvasive total hemoglobin measurement.

Authors:  Kye Jin Jeon; Su-Jin Kim; Kun Kook Park; Jong-Won Kim; Gilwon Yoon
Journal:  J Biomed Opt       Date:  2002-01       Impact factor: 3.170

2.  Signal processing methods for pulse oximetry.

Authors:  T L Rusch; R Sankar; J E Scharf
Journal:  Comput Biol Med       Date:  1996-03       Impact factor: 4.589

3.  Absorption and multiple scattering by biological suspensions.

Authors:  V Twersky
Journal:  J Opt Soc Am       Date:  1970-08

4.  Role of light scattering in whole blood oximetry.

Authors:  J M Steinke; A P Shepherd
Journal:  IEEE Trans Biomed Eng       Date:  1986-03       Impact factor: 4.538

  4 in total
  2 in total

Review 1.  Emerging point-of-care technologies for anemia detection.

Authors:  Ran An; Yuning Huang; Yuncheng Man; Russell W Valentine; Erdem Kucukal; Utku Goreke; Zoe Sekyonda; Connie Piccone; Amma Owusu-Ansah; Sanjay Ahuja; Jane A Little; Umut A Gurkan
Journal:  Lab Chip       Date:  2021-05-18       Impact factor: 6.799

Review 2.  Analysis of Uncertainty and Variability in Finite Element Computational Models for Biomedical Engineering: Characterization and Propagation.

Authors:  Nerea Mangado; Gemma Piella; Jérôme Noailly; Jordi Pons-Prats; Miguel Ángel González Ballester
Journal:  Front Bioeng Biotechnol       Date:  2016-11-07
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.