Literature DB >> 15740899

On-line capillary isoelectric focusing-mass spectrometry for quantitative analysis of peptides and proteins.

Yukihiro Kuroda1, Hideo Yukinaga, Masahiro Kitano, Taeko Noguchi, Mahboob Nemati, Akimasa Shibukawa, Terumichi Nakagawa, Katsumi Matsuzaki.   

Abstract

On-line capillary isoelectric focusing-mass spectrometry (cIEF-MS) was applied to determine concentrations of peptides and proteins using angiotensin II and human tetrasialo-transferrin as the model samples. The concentration of the carrier ampholyte was optimized for both resolution and ion intensity. cIEF-MS employing 1% Pharmalyte 3-10 and a sheath liquid containing water/methanol/acetic acid (50/49/1) resolved angiotensin I and II (5 microM each, DeltapI=0.2) at an Rs value of 2.29. The determined concentration of angiotensin II (0.1-5 microM) well correlated (R=0.999) with that obtained by the conventional RP-HPLC method. The limit of detection was 0.22 microM, which was about 10 times lower than that by UV detection (2 microM). The repeatability and accuracy were <15 and <11%, respectively. cIEF-MS was also applied to determine human tetrasialo-transferrin concentration. The good linearity (R2=0.998) was also observed between the transferrin concentration (0.5-1.2 g/L) and peak area ratio (IS; beta-lactoglobulin B) with acceptable accuracy (<1.9%) and repeatability ( approximately 10% at 1g/L).

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15740899     DOI: 10.1016/j.jpba.2004.11.025

Source DB:  PubMed          Journal:  J Pharm Biomed Anal        ISSN: 0731-7085            Impact factor:   3.935


  7 in total

1.  Recent advances in the analysis of therapeutic proteins by capillary and microchip electrophoresis.

Authors:  Jessica S Creamer; Nathan J Oborny; Susan M Lunte
Journal:  Anal Methods       Date:  2014-07-08       Impact factor: 2.896

2.  Poly(glycidyl methacrylate-divinylbenzene) based immobilized pH gradient capillary isoelectric focusing coupling with MALDI mass spectrometry for enhanced neuropeptide analysis.

Authors:  Zichuan Zhang; Junhua Wang; Limei Hui; Lingjun Li
Journal:  Electrophoresis       Date:  2012-02       Impact factor: 3.535

3.  Membrane-assisted capillary isoelectric focusing coupling with matrix-assisted laser desorption/ionization-Fourier transform mass spectrometry for neuropeptide analysis.

Authors:  Zichuan Zhang; Junhua Wang; Limei Hui; Lingjun Li
Journal:  J Chromatogr A       Date:  2011-05-27       Impact factor: 4.759

4.  Development of a Chip/Chip/SRM platform using digital chip isoelectric focusing and LC-Chip mass spectrometry for enrichment and quantitation of low abundance protein biomarkers in human plasma.

Authors:  Agnes Rafalko; Shujia Dai; William S Hancock; Barry L Karger; Marina Hincapie
Journal:  J Proteome Res       Date:  2011-12-27       Impact factor: 4.466

5.  On-line amino acid-based capillary isoelectric focusing-ESI-MS/MS for protein digests analysis.

Authors:  Guijie Zhu; Liangliang Sun; Ping Yang; Norman J Dovichi
Journal:  Anal Chim Acta       Date:  2012-04-27       Impact factor: 6.558

6.  Electrothermal supercharging of proteins in native MS: effects of protein isoelectric point, buffer, and nanoESI-emitter tip size.

Authors:  Daniel N Mortensen; Evan R Williams
Journal:  Analyst       Date:  2016-07-21       Impact factor: 4.616

Review 7.  Recent developments in CE and CEC of peptides.

Authors:  Václav Kasicka
Journal:  Electrophoresis       Date:  2008-01       Impact factor: 3.535

  7 in total