Biomechanical evaluation of a bioresorbable odontoid screw.

Christopher P Ames1, Neil R Crawford, Robert H Chamberlain, Vivek Deshmukh, Belma Sadikovic, Volker K H Sonntag.   

Abstract

OBJECT: The authors tested the ability of a resorbable cannulated lag screw composed of a polylactide copolymer to repair Type II odontoid fractures. The resorbable screw was evaluated for its ability to restore strength and stiffness to the fractured odontoid process compared with traditional titanium screws.
METHODS: Type II odontoid fractures were created in 14 human cadaveric C-2 vertebrae by applying a posterolaterally directed load and piston displacement was measured. Seven of these specimens were repaired using metal screws and seven were repaired using resorbable screws. Specimens were reinjured using the same mechanism as the initial fracture. Values of ultimate strength and stiffness during failure were statistically compared between metal and resorbable screws and between initial fracture and reinjury.
CONCLUSIONS: The stiffness and ultimate strength during initial fracture were significantly greater than those during reinjury in specimens repaired using resorbable screws or titanium screws (p < 0.001). The resorbable and titanium screws both restored 31% of the initial ultimate strength of the intact specimen (p = 0.95). The stiffness of the fractured odontoid process was restored to 15 and 23% of its initial value by repair with resorbable and metal screws, respectively (p = 0.07). The mode of failure in resorbable screws was usually breakage or bending, whereas that in metal screws was consistently cutout of the proximal shaft of the screw through the anterior C-2 vertebral body.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15739531     DOI: 10.3171/spi.2005.2.2.0182

Source DB:  PubMed          Journal:  J Neurosurg Spine        ISSN: 1547-5646


  2 in total

1.  One-screw fixation provides similar stability to that of two-screw fixation for type II dens fractures.

Authors:  Gang Feng; Robert Wendlandt; Sebastian Spuck; Arndt P Schulz
Journal:  Clin Orthop Relat Res       Date:  2012-05-15       Impact factor: 4.176

2.  Biomechanical Assessment of Stabilization of Simulated Type II Odontoid Fracture with Case Study.

Authors:  Roy T Daniel; Mir M Hussain; Noelle Klocke; Soumya S Yandamuri; Lukas Bobinski; John M Duff; Brandon S Bucklen
Journal:  Asian Spine J       Date:  2017-02-17
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.