Literature DB >> 15738553

Reliability of automated blood pressure devices used by hypertensive patients.

William C W Wong1, Ivan K L Shiu, Thomas M T Hwong, James A Dickinson.   

Abstract

Automated blood pressure (BP) devices are used by many hypertensive patients in Hong Kong, with or without medical advice. At two community clinics, we invited hypertensive patients aged between 40 and 70 years who used such a device to fill in a questionnaire and to have four sets of BP measurements, automated and mercury, at two visits. Of 290 hypertensive patients 120 fulfilled the criteria, and 73 of these agreed to participate. 53 devices measured arm BP, 21 measured forearm BP. The agreement between the mercury sphygmomanometer and the automated devices was poor, with average differences of 9.5 mmHg for systolic and 9.4 mmHg for diastolic and no clear advantage for either site of measurement. As a means of screening for BP >140/90 mmHg the sensitivity of the automated devices was 81% and the specificity was 80%. There were large variations in how often and under what circumstances the devices had been used. One-fifth of the devices had been acquired on medical advice but only 11% of the participants were aware of the three important conditions for operating such devices. Discussion of automated devices, their role and proper use, should now be part of routine hypertensive care.

Entities:  

Mesh:

Year:  2005        PMID: 15738553      PMCID: PMC1079411          DOI: 10.1177/014107680509800306

Source DB:  PubMed          Journal:  J R Soc Med        ISSN: 0141-0768            Impact factor:   18.000


  13 in total

Review 1.  Use and interpretation of ambulatory blood pressure monitoring: recommendations of the British hypertension society.

Authors:  E O'Brien; A Coats; P Owens; J Petrie; P L Padfield; W A Littler; M de Swiet; F Mee
Journal:  BMJ       Date:  2000-04-22

2.  Blood pressure measuring devices: recommendations of the European Society of Hypertension.

Authors:  E O'Brien; B Waeber; G Parati; J Staessen; M G Myers
Journal:  BMJ       Date:  2001-03-03

3.  White coat hypertension: not so benign after all?

Authors:  Irene Chung; Gregory Y H Lip
Journal:  J Hum Hypertens       Date:  2003-12       Impact factor: 3.012

4.  Fifteen-year trends in cardiovascular risk factors (1980-1982 through 1995-1997): the Minnesota Heart Survey.

Authors:  Donna K Arnett; Paul G McGovern; David R Jacobs; Eyal Shahar; Sue Duval; Henry Blackburn; Russell V Luepker
Journal:  Am J Epidemiol       Date:  2002-11-15       Impact factor: 4.897

5.  Distribution of blood pressure and hypertension in Canada and the United States.

Authors:  M R Joffres; P Hamet; D R MacLean; G J L'italien; G Fodor
Journal:  Am J Hypertens       Date:  2001-11       Impact factor: 2.689

6.  Diagnosis of hypertension using home or ambulatory blood pressure monitoring: comparison with the conventional strategy based on repeated clinic blood pressure measurements.

Authors:  G S Stergiou; I I Skeva; N M Baibas; C B Kalkana; L G Roussias; T D Mountokalakis
Journal:  J Hypertens       Date:  2000-12       Impact factor: 4.844

7.  Home blood pressure as a predictor of future blood pressure stability in borderline hypertension. The Tecumseh Study.

Authors:  S D Nesbitt; J V Amerena; E Grant; K A Jamerson; H Lu; A Weder; S Julius
Journal:  Am J Hypertens       Date:  1997-11       Impact factor: 2.689

Review 8.  Task force VI: Self-monitoring of the blood pressure.

Authors:  W B White; R Asmar; Y Imai; G A Mansoor; P Padfield; L Thijs; B Waeber
Journal:  Blood Press Monit       Date:  1999-12       Impact factor: 1.444

Review 9.  Blood Pressure Monitoring. Task force III: Target-organ damage, morbidity and mortality.

Authors:  P Verdecchia; D Clement; R Fagard; P Palatini; G Parati
Journal:  Blood Press Monit       Date:  1999-12       Impact factor: 1.444

10.  The association between physical activity and the development of acute coronary syndromes in treated and untreated hypertensive subjects.

Authors:  Christine Chrysohoou; Christos Pitsavos; Demosthenes B Panagiotakos; Peter F Kokkinos; Christodoulos Stefanadis; Pavlos Toutouzas
Journal:  J Clin Hypertens (Greenwich)       Date:  2003 Mar-Apr       Impact factor: 3.738

View more
  4 in total

1.  Managing white-coat effect.

Authors:  Joel Handler
Journal:  J Clin Hypertens (Greenwich)       Date:  2008-08       Impact factor: 3.738

2.  A trial for the use of qigong in the treatment of pre and mild essential hypertension: a study protocol for a randomized controlled trial.

Authors:  Ji-Eun Park; Yan Liu; Taeseob Park; Sanghoon Hong; Jung-Eun Kim; Tae-Hun Kim; Ae-Ran Kim; So-Young Jung; Hyoju Park; Sun-Mi Choi
Journal:  Trials       Date:  2011-11-21       Impact factor: 2.279

3.  Goodbye mercury? Blood pressure measurement and its future.

Authors:  George I Varughese; Gregory Y H Lip
Journal:  J R Soc Med       Date:  2005-03       Impact factor: 18.000

4.  How Accurate Are Home Blood Pressure Devices in Use? A Cross-Sectional Study.

Authors:  Marcel Ruzicka; Ayub Akbari; Eva Bruketa; Jeanne Françoise Kayibanda; Claude Baril; Swapnil Hiremath
Journal:  PLoS One       Date:  2016-06-01       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.