Literature DB >> 15737149

Day care center characteristics and children's respiratory health.

P Nafstad1, J J K Jaakkola, A Skrondal, P Magnus.   

Abstract

UNLABELLED: Day care centers provide an important exposure arena with potential harmful health effects for children. This study has linked health effect data from a survey among 942 3-5-year-old Oslo children with information on day care center characteristics collected during inspection of the 175 day care centers these children attended. The aim of the study was to estimate associations between dampness problems and other building characteristics and several respiratory health outcomes. Dampness problems (sign of molds, water leakage, damage to floor/wall) were observed in 51% of the day care centers. In multiple logistic regression analyses none of the studied symptoms and diseases (nightly cough, blocked or runny nose without common cold, wheeze, heavy breathing or chest tightness, the common cold, tonsillitis/pharyngitis, otitis media, bronchitis, pneumonia, asthma, and allergic rhinitis) were systematically associated with dampness problems or type of ventilation in day care centers. None of the studied indicators of day care center exposures were found to have a clear effect on day care children's respiratory health. Even so this study does not rule out negative health effects of day care center exposures. The study demonstrates that population-based studies of these relations are demanding with regard to assessment of exposure and health outcomes. PRACTICAL IMPLICATIONS: Simple and easy-to-register indicators of exposures like dampness problems and type of ventilation assessed in 175 day care centers were not related to respiratory health among 3-5-year-old Norwegian children attending the day care centers. The study does not rule out negative health effects of day care center exposures, but demonstrates methodological challenges needed to be addressed in studies of health effects of the day care environment.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15737149     DOI: 10.1111/j.1600-0668.2004.00310.x

Source DB:  PubMed          Journal:  Indoor Air        ISSN: 0905-6947            Impact factor:   5.770


  5 in total

1.  Indoor and outdoor airborne bacteria in child day-care centers in Edirne City (Turkey), seasonal distribution and influence of meteorological factors.

Authors:  Halide Aydogdu; Ahmet Asan; Muserref Tatman Otkun
Journal:  Environ Monit Assess       Date:  2009-04-29       Impact factor: 2.513

2.  Life events, chronic stressors, and depressive symptoms in low-income urban mothers with asthmatic children.

Authors:  Joan Kub; Jacky M Jennings; Michele Donithan; Jennifer M Walker; Cassia Lewis Land; Arlene Butz
Journal:  Public Health Nurs       Date:  2009 Jul-Aug       Impact factor: 1.462

3.  An empirical approach to sufficient similarity: combining exposure data and mixtures toxicology data.

Authors:  Scott Marshall; Chris Gennings; Linda K Teuschler; Leanna G Stork; Rogelio Tornero-Velez; Kevin M Crofton; Glenn E Rice
Journal:  Risk Anal       Date:  2013-02-11       Impact factor: 4.000

4.  Airborne fungi in child day care centers in Edirne City, Turkey.

Authors:  Halide Aydogdu; Ahmet Asan
Journal:  Environ Monit Assess       Date:  2008-02-09       Impact factor: 2.513

Review 5.  Which Meso-Level Characteristics of Early Childhood Education and Care Centers Are Associated with Health, Health Behavior, and Well-Being of Young Children? Findings of a Scoping Review.

Authors:  Raphael M Herr; Katharina Diehl; Sven Schneider; Nina Osenbruegge; Nicole Memmer; Steffi Sachse; Stephanie Hoffmann; Benjamin Wachtler; Max Herke; Claudia R Pischke; Anna Novelli; Jennifer Hilger-Kolb
Journal:  Int J Environ Res Public Health       Date:  2021-05-07       Impact factor: 3.390

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.