Literature DB >> 15735783

24 h diffusive sampling of toxic VOCs in air onto Carbopack X solid adsorbent followed by thermal desorption/GC/MS analysis-laboratory studies.

William A McClenny1, Karen D Oliver, Henry H Jacumin, E Hunter Daughtrey, Donald A Whitaker.   

Abstract

Diffusive sampling of a mixture of 42 volatile organic compounds (VOCs) in humidified, purified air onto the solid adsorbent Carbopack X was evaluated under controlled laboratory conditions. The evaluation included variations in sample air temperature, relative humidity and ozone concentration. Linearity of samples with loading was examined both for a constant concentration with time varied up to 24 h and for different concentrations over 24 h. Reverse diffusion and its increase with accumulation of sample were determined for all compounds. Tubes were examined for blank levels, change of blanks with storage time, and variability of blanks. Method detection limits were determined based on seven replicate samples. Based on this evaluation, 27 VOCs were selected for quantitative monitoring in the concentration range from approximately 0.1 to 4 ppbv. Comparison results of active and diffusive samples taken over 24 h and under the same simulated ambient conditions at a constant 2 ppbv were interpreted to estimate the effective diffusive sampling rates (ml min(-1)) and their uncertainties and to calculate the corresponding diffusive uptake rates (ng ppmv(-1) min(-1)).

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15735783     DOI: 10.1039/b412213e

Source DB:  PubMed          Journal:  J Environ Monit        ISSN: 1464-0325


  3 in total

1.  Sample integrity evaluation and EPA method 325B interlaboratory comparison for select volatile organic compounds collected diffusively on Carbopack X sorbent tubes.

Authors:  Karen D Oliver; Tamira A Cousett; Donald A Whitaker; Luther A Smith; Shaibal Mukerjee; Casson Stallings; Eben D Thoma; Lillian Alston; Maribel Colon; Tai Wu; Stacy Henkle
Journal:  Atmos Environ (1994)       Date:  2017-08       Impact factor: 4.798

2.  Calibration and performance of synchronous SIM/scan mode for simultaneous targeted and discovery (non-targeted) analysis of exhaled breath samples from firefighters.

Authors:  M Ariel Geer Wallace; Joachim D Pleil; Sibel Mentese; Karen D Oliver; Donald A Whitaker; Kenneth W Fent
Journal:  J Chromatogr A       Date:  2017-07-28       Impact factor: 4.759

3.  South Philadelphia passive sampler and sensor study.

Authors:  Eben D Thoma; Halley L Brantley; Karen D Oliver; Donald A Whitaker; Shaibal Mukerjee; Bill Mitchell; Tai Wu; Bill Squier; Elsy Escobar; Tamira A Cousett; Carol Ann Gross-Davis; Howard Schmidt; Dennis Sosna; Hallie Weiss
Journal:  J Air Waste Manag Assoc       Date:  2016       Impact factor: 2.235

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.