Literature DB >> 15734372

CryoLife-O'Brien stentless valve: 10-year results of 402 implants.

Mark F O'Brien1, Michael A H Gardner, Bruce Garlick, Homayoun Jalali, Julie A Gordon, Sarah L Whitehouse, Wendy E Strugnell, Richard Slaughter.   

Abstract

BACKGROUND: This truly stentless porcine valve is composite, without Dacron, and implanted supra-annularly. Ten-year analysis with magnetic resonance imaging is presented.
METHODS: From 1992 to 2002, 402 patients (mean 73.5 years) had aortic valve replacement. Associated procedures were required in 252 patients (63%). Serial echoes provided 1340 studies. Clinical follow-up was 100%. Magnetic resonance imaging focused on aortic annulus extensibility.
RESULTS: The 30-day mortality was 0.99% (4 deaths). Morbidity comprised thromboembolism (40 patients including 18 patients with permanent strokes); endocarditis (9 patients); and reoperation (9 patients [periprosthetic leak, 2; endocarditis, 5; technical needle damage, 1; and structural degeneration, 1]). Of 402 valves more than 10 years, five valves were explanted, one only for structural failure. Except for endocarditis (2 patients), no late deaths (69 patients, 1.5 months to 5.7 years) were valve related. Echocardiography demonstrated low gradients with good orifice areas, excellent ventricular regression (p = 0.0001 preoperative and postoperative comparisons) and late incompetence (mild in 45 patients and moderate in 9 patients). No living patient has severe incompetence. Magnetic resonance imaging demonstrated the annulus 'expanding and relaxing' throughout the cardiac cycle, the mean increase in cross-sectional area being 37%, resembling normal aortic root dynamics.
CONCLUSIONS: Elderly patients received this hemodynamically acceptable valve with its simple, supra-annular implantation and satisfactory mid-term morbid-free lifestyle to 10 years maximum follow-up. With only one structural failure, restoration of valve annular extensibility may have a favorable influence on long-term durability.

Entities:  

Mesh:

Year:  2005        PMID: 15734372     DOI: 10.1016/j.athoracsur.2004.08.057

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  3 in total

Review 1.  A look at recent improvements in the durability of tissue valves.

Authors:  Takahiro Nishida; Ryuji Tominaga
Journal:  Gen Thorac Cardiovasc Surg       Date:  2013-01-24

2.  Evaluation of platelet count after isolated biological aortic valve replacement with Freedom Solo bioprosthesis.

Authors:  Antonio Miceli; Daniyar Gilmanov; Michele Murzi; Maria S Parri; Alfredo G Cerillo; Stefano Bevilacqua; Pier A Farneti; Mattia Glauber
Journal:  Eur J Cardiothorac Surg       Date:  2012-01       Impact factor: 4.191

Review 3.  Stentless aortic valve replacement: an update.

Authors:  Junjiro Kobayashi
Journal:  Vasc Health Risk Manag       Date:  2011-06-02
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.