Literature DB >> 15733791

To smooth or not to smooth? ROC analysis of perfusion fMRI data.

Jiongjiong Wang1, Ze Wang, Geoffrey K Aguirre, John A Detre.   

Abstract

Blood oxygenation level dependent (BOLD) contrast has been widely used for visualizing regional neural activation. Temporal filtering and parameter estimation algorithms are generally used to account for the intrinsic temporal autocorrelation present in BOLD data. Arterial spin labeling perfusion imaging is an emerging methodology for visualizing regional brain function both at rest and during activation. Perfusion contrast manifests different noise properties compared with BOLD contrast, represented by the even distribution of noise power and spatial coherence across the frequency spectrum. Consequently, different strategies are expected to be employed in the statistical analysis of functional magnetic resonance imaging (fMRI) data based on perfusion contrast. In this study, the effect of different analysis methods upon signal detection efficacy, as assessed by receiver operator characteristic (ROC) measures, was examined for perfusion fMRI data. Simulated foci of neural activity of varying amplitude and spatial extent were added to resting perfusion data, and the accuracy of each analysis was evaluated by comparing the results with the known distribution of pseudo-activation. In contrast to the BOLD fMRI, temporal smoothing or filtering reduces the power of perfusion fMRI data analyses whereas spatial smoothing is beneficial to the efficacy of analyses.

Mesh:

Substances:

Year:  2005        PMID: 15733791     DOI: 10.1016/j.mri.2004.11.009

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  21 in total

1.  Functional imaging of implicit marijuana associations during performance on an Implicit Association Test (IAT).

Authors:  Susan L Ames; Jerry L Grenard; Alan W Stacy; Lin Xiao; Qinghua He; Savio W Wong; Gui Xue; Reinout W Wiers; Antoine Bechara
Journal:  Behav Brain Res       Date:  2013-09-09       Impact factor: 3.332

2.  Comparison of spatial and temporal pattern for fMRI obtained with BOLD and arterial spin labeling.

Authors:  A Federspiel; T J Müller; H Horn; C Kiefer; W K Strik
Journal:  J Neural Transm (Vienna)       Date:  2006-04-11       Impact factor: 3.575

Review 3.  Statistical approaches to functional neuroimaging data.

Authors:  F Dubois Bowman; Ying Guo; Gordana Derado
Journal:  Neuroimaging Clin N Am       Date:  2007-11       Impact factor: 2.264

4.  Support vector machine learning-based fMRI data group analysis.

Authors:  Ze Wang; Anna R Childress; Jiongjiong Wang; John A Detre
Journal:  Neuroimage       Date:  2007-04-27       Impact factor: 6.556

5.  Empirical optimization of ASL data analysis using an ASL data processing toolbox: ASLtbx.

Authors:  Ze Wang; Geoffrey K Aguirre; Hengyi Rao; Jiongjiong Wang; María A Fernández-Seara; Anna R Childress; John A Detre
Journal:  Magn Reson Imaging       Date:  2007-09-10       Impact factor: 2.546

6.  An iterative two-threshold analysis for single-subject functional MRI of the human brain.

Authors:  Tibor Auer; Renate Schweizer; Jens Frahm
Journal:  Eur Radiol       Date:  2011-06-28       Impact factor: 5.315

7.  Support vector machine learning-based cerebral blood flow quantification for arterial spin labeling MRI.

Authors:  Ze Wang
Journal:  Hum Brain Mapp       Date:  2014-01-17       Impact factor: 5.038

8.  Effects of different smoothing on global and regional resting functional connectivity.

Authors:  Adnan A S Alahmadi
Journal:  Neuroradiology       Date:  2020-08-25       Impact factor: 2.804

9.  Eccentricity mapping of the human visual cortex to evaluate temporal dynamics of functional T1ρ mapping.

Authors:  Hye-Young Heo; John A Wemmie; Casey P Johnson; Daniel R Thedens; Vincent A Magnotta
Journal:  J Cereb Blood Flow Metab       Date:  2015-05-13       Impact factor: 6.200

10.  Caffeine dose effect on activation-induced BOLD and CBF responses.

Authors:  Yufen Chen; Todd B Parrish
Journal:  Neuroimage       Date:  2009-03-13       Impact factor: 6.556

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.