Literature DB >> 15733762

The value of portable ultrasound for evaluation of cardiomegaly patients presenting at the emergency department.

Shih-Chi Liu1, Wei-Tien Chang, Chien-Hua Huang, Te-I Weng, Huei-Ming Ma Matthew, Wen-Jone Chen.   

Abstract

OBJECTIVES: The purpose of this study was to evaluate the value of a hand-carried portable ultrasound device in the emergency department for patients with cardiomegaly and evaluate its impact on diagnosis and treatment. We compared the results of the portable ultrasound with the results of physical examination and with standard echocardiograph (SE) in the cardiomegaly patients in emergency department.
BACKGROUND: Recently, small portable ultrasound devices have been introduced, and they need more extensive study to evaluate their application.
METHODS: We used the OptiGo (Agilent Technologies, Andover, MA) portable device to evaluate emergency patients, and compared it with two SE devices available for this study, the Hewlett Packard (Sono 5500; Andover, MA) or the Vingmed (System V; Horten, Norway). Each of 100 patients was studied by physical examination first then examined with the portable ultrasound and standard echocardiography. The yields from physical examination and portable echocardiography were compared and results of the standard and portable were also compared.
RESULTS: There were a total of 243 cardiovascular findings detected by the standard echocardiographic examination in the 100 patients studied. Cardiac examination failed to detect 40% of the overall findings but the portable device missed only 17% of all findings. The portable device evaluated 201 conditions correctly (83%) and missed relevant clinical findings in 37 (17%) as compared to standard echocardiography, but in only 12 (5%) were these findings of major importance As an overall measure of diagnostic value, the portable device would have added to clinical judgment, thus boosting diagnostic accuracy from 62% to 83%.
CONCLUSIONS: Portable ultrasound technology can provide rapid, readily available and important clinical information for emergency physicians in the management of emergency patients with cardiomegaly.

Entities:  

Mesh:

Year:  2005        PMID: 15733762     DOI: 10.1016/j.resuscitation.2004.09.009

Source DB:  PubMed          Journal:  Resuscitation        ISSN: 0300-9572            Impact factor:   5.262


  3 in total

1.  Diagnostic accuracy of tissue Doppler echocardiography for patients with acute heart failure.

Authors:  C-H Huang; M-S Tsai; C-C Hsieh; T-D Wang; W-T Chang; W-J Chen
Journal:  Heart       Date:  2006-06-27       Impact factor: 5.994

2.  Perioperative focused cardiac ultrasound: a brief report.

Authors:  Amish Sheth; Anahita Dabo-Trubelja
Journal:  J Anesth Crit Care       Date:  2021-02-16

3.  [Usefulness and reliability of point of care ultrasound in Family Medicine: Focused cardiac and lung ultrasound].

Authors:  Santiago Diaz Sánchez; Laura Conangla Ferrín; Ignacio Manuel Sánchez Barrancos; Jesús Pujol Salud; José Antonio Tarrazo Suárez; José Manuel Morales Cano
Journal:  Aten Primaria       Date:  2019-01-23       Impact factor: 1.137

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.