Literature DB >> 1572743

Gated technetium-99m methoxy-isobutylisonitrile perfusion imaging.

P G Avery1, N M Hudson, P J Hubner.   

Abstract

Technetium-99m methoxy-isobutylisonitrile, has been shown to be a useful perfusion agent for detecting coronary artery disease. Gated acquisition of perfusion images may remove motion artefact and improve detection. We compared the results of sensitivity and specificity for detecting coronary artery disease using perfusion images from the whole cardiac cycle (ungated) or from end-diastolic (gated) frames in 46 subjects, 31 with significant coronary disease and 15 with normal coronary arteries. There was no significant difference in detection of patients with coronary disease between the ungated and end-diastolic images: 25/31 with the ungated image and 28/31 with the end-diastolic. An improvement was made in detecting defects in the left anterior descending artery territory: 17/20 with the end-diastolic vs 11/20 with the ungated image (P less than 0.05) and in the right coronary artery region: 16/21 vs 10/21 (P less than 0.05), with an overall improvement in detecting regions supplied by stenosed coronary arteries: 45/55 end-diastolic vs 31/55 ungated (P less than 0.01). These results suggest use of the end-diastolic frame can significantly enhance the diagnostic capacity of methoxy-isobutylisonitrile perfusion imaging.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1572743     DOI: 10.1016/0167-5273(92)90181-2

Source DB:  PubMed          Journal:  Int J Cardiol        ISSN: 0167-5273            Impact factor:   4.164


  3 in total

1.  Exercise gated planar myocardial perfusion imaging using technetium-99m sestamibi for the diagnosis of coronary artery disease: an alternative to exercise tomographic imaging.

Authors:  F Jamar; R Topcuoglu; F Cauwe; P De Coster; V Roelants; C Beckers; W Wijns; J A Melin
Journal:  Eur J Nucl Med       Date:  1995-01

2.  The influence of gating on measurements of myocardium at risk and infarct size during acute myocardial infarction by tomographic technetium 99m-labeled sestamibi imaging.

Authors:  T F Christian; M K O'Connor; R B Glynn; P J Rogers; R J Gibbons
Journal:  J Nucl Cardiol       Date:  1995 May-Jun       Impact factor: 5.952

3.  Diagnostic value and incremental contribution of bicycle exercise, first-pass radionuclide angiography, and 99mTc-labeled sestamibi single-photon emission computed tomography in the identification of coronary artery disease in patients without infarction.

Authors:  A S Hambÿe; A Vervaet; S Lieber; R Ranquin
Journal:  J Nucl Cardiol       Date:  1996 Nov-Dec       Impact factor: 5.952

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.