Literature DB >> 15726890

Formaldehyde concentration in the air and in cadavers at the gross anatomy laboratory in Hiroshima University.

Tomoyuki Kurose1, Haruto Kodera, Hirohiko Aoyama, Seiichi Kawamata.   

Abstract

The formaldehyde concentration in the air and in various tissues of 35 human cadavers were measured during a gross anatomy course held at the Faculty of Medicine of Hiroshima University in the 2003 educational year. Atmospheric formaldehyde levels were 0.25-0.55 ppm and thus less than the upper limit of the guideline for formaldehyde exposure (0.5 ppm) set by the Japan Society for Occupational Health (1988) except for one out of 10 measurements. The formaldehyde concentrations in tissues were as follows: the lung, 0.12 +/- 0.09% (n=29); the liver, 0.12 +/- 0.09% (n=29); and the brachioradialis muscle, 0.11 +/- 0.09% (n=30). Considerable variation was found among the cadavers and these values were lower than those of Tsurumi University which provided the only other data (average formaldehyde concentrations ranged from 0.27 to 0.32%). At Hiroshima University, blood is allowed to drain during embalming, whereas it is not at Tsurumi University. Differences in the embalming procedure are thus responsible for low and fluctuating formaldehyde concentrations in cadavers at Hiroshima University, and it is conceivable that relatively low formaldehyde levels in the air result from low formaldehyde concentrations in cadavers and good room ventilation (10 room-air changes per hour). However, the Japanese Ministry of Health and Welfare recommended lower formaldehyde exposure levels (0.08 or 0.25 ppm) in 2002. Thus, it may be necessary to further reduce formaldehyde levels in the gross anatomy laboratory by means of such measures as neutralizing formaldehyde with ammonium carbonate; using a locally ventilated dissection work-table, etc.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15726890

Source DB:  PubMed          Journal:  Hiroshima J Med Sci        ISSN: 0018-2052


  5 in total

1.  Formaldehyde in the indoor environment.

Authors:  Tunga Salthammer; Sibel Mentese; Rainer Marutzky
Journal:  Chem Rev       Date:  2010-04-14       Impact factor: 60.622

2.  Formaldehyde exposure in gross anatomy laboratory of Suranaree University of Technology: a comparison of area and personal sampling.

Authors:  Naruwan Saowakon; Piyada Ngernsoungnern; Pornpun Watcharavitoon; Apichart Ngernsoungnern; Rachain Kosanlavit
Journal:  Environ Sci Pollut Res Int       Date:  2015-08-02       Impact factor: 4.223

3.  A strategy for the reduction of formaldehyde concentration in a hospital pathology laboratory.

Authors:  Masanori Ogawa; Isamu Kabe; Yasuhiro Terauchi; Shigeru Tanaka
Journal:  J Occup Health       Date:  2019-01       Impact factor: 2.708

Review 4.  Occupational scenarios and exposure assessment to formaldehyde: A systematic review.

Authors:  Vittoria Cammalleri; Roberta Noemi Pocino; Daniela Marotta; Carmela Protano; Federica Sinibaldi; Stefano Simonazzi; Marta Petyx; Sergio Iavicoli; Matteo Vitali
Journal:  Indoor Air       Date:  2021-10-27       Impact factor: 6.554

5.  Occupational exposure of a medical school staff to formaldehyde in tehran.

Authors:  Mansour R Azari; Parisa Asadi; Mohammad Javad Jafari; Hamid Soori; Vajihe Hosseini
Journal:  Tanaffos       Date:  2012
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.