Literature DB >> 15726072

Total shoulder arthroplasty: glenoid component design.

Gerald R Williams1, Joseph A Abboud.   

Abstract

Although Charles Neer's original glenoid component underwent several modifications, the all-polyethylene, keeled component with a radius of curvature that conformed to the humeral radius of curvature and that was implanted with cement became the glenoid implant of choice. Neer reported approximately a 30% incidence of radiolucent lines; however, only 2 of 615 glenoids were revised for loosening. Other surgeons have reported radiolucent lines in up to 90% of glenoid components and have correlated symptoms with increasing radiolucencies. This has led to the development of alternative glenoid components for unconstrained total shoulder arthroplasty. Variations in component design include component shape, articular conformity, method of fixation, and material composition. The purposes of this presentation are to review the performance of the original Neer design, as well as other more recent glenoid designs, to identify factors that may influence the performance of glenoid components, and to provide a rationale for future changes in glenoid component design.

Entities:  

Mesh:

Year:  2005        PMID: 15726072     DOI: 10.1016/j.jse.2004.09.028

Source DB:  PubMed          Journal:  J Shoulder Elbow Surg        ISSN: 1058-2746            Impact factor:   3.019


  6 in total

1.  Computed tomography morphological analysis of the scapula and its implications in shoulder arthroplasty.

Authors:  Catarina N Damas; Joana Silva; Márcia C Sá; João Torres
Journal:  Eur J Orthop Surg Traumatol       Date:  2015-11-14

2.  The glenoid in total shoulder arthroplasty.

Authors:  Mark Schrumpf; Travis Maak; Sommer Hammoud; Edward V Craig
Journal:  Curr Rev Musculoskelet Med       Date:  2011-12

3.  Porous metals and alternate bearing surfaces in shoulder arthroplasty.

Authors:  Shannon R Carpenter; Ivan Urits; Anand M Murthi
Journal:  Curr Rev Musculoskelet Med       Date:  2016-03

4.  Number of pegs influence focal stress distributions and micromotion in glenoid implants: a finite element study.

Authors:  Abdul Hadi Abdul Wahab; Mohammed Rafiq Abdul Kadir; Muhammad Noor Harun; Tunku Kamarul; Ardiyansyah Syahrom
Journal:  Med Biol Eng Comput       Date:  2016-06-02       Impact factor: 2.602

5.  New design of a cementless glenoid component in unconstrained shoulder arthroplasty: a prospective medium-term analysis of 143 cases.

Authors:  D Katz; J Kany; P Valenti; P Sauzières; P Gleyze; K El Kholti
Journal:  Eur J Orthop Surg Traumatol       Date:  2012-10-27

6.  Three-Dimensional Morphometric Analysis of Penetrative Depth and Size of Nonarthritic and Degenerative Arthritic Glenoids: Implications for Glenoid Replacement in Shoulder Arthroplasty.

Authors:  Hong Jun Jung; Tae-Seok Nam; Daewon Park; In-Ho Jeon
Journal:  Clin Orthop Surg       Date:  2020-05-14
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.