Influence of cataract surgery on corneal endothelial cell density estimation.

Christopher Wirbelauer1, Gregor Wollensak, Duy Thoai Pham.   

Abstract

PURPOSE: To assess the effect of cataract surgery on semiautomated human corneal endothelial cell density (ECD) estimation using noncontact specular microscopy.
METHODS: In this prospective clinical study, 62 consecutive patients undergoing cataract surgery were studied. To evaluate possible variations of accuracy and agreement under clinical circumstances, the corneal ECD was determined before and after cataract surgery. The parameter ECD (cells/mm) in the central and paracentral cornea was consecutively determined with 2 algorithms available in a noncontact specular microscope [fixed-frame method (FFM) and automatic center method (ACM)]. The postoperative evaluation was performed at 1 day, after 4 weeks, and after 6 months. The accuracy, the relative error, and the 95% limits of agreement (LoA) were determined for both counting methods.
RESULTS: The overall group-averaged accuracy was -19.4 cells/mm (0.86%) centrally and -17.3 cells/mm (0.76%) paracentrally. The LoA (95% CI) were within 234 cells/mm (10.4%) and 250 cells/mm (10.9%), respectively. After cataract surgery, a slight decrease in accuracy was noted in the central (2.09%) and paracentral areas (1.76%). The relative error increased from 3.66% to 6.02% centrally and from 4.96% to 6.55% paracentrally. The LoA (95% CI) increased from +/-194 cells/mm to +/-304 cells/mm centrally and from +/-275 cells/mm to +/-322 cells/mm paracentrally. In the later postoperative period, endothelial stabilization improved the accuracy and agreement in ECD estimation.
CONCLUSIONS: The estimation of ECD after cataract surgery employing current algorithms was achieved with a clinically acceptable level of accuracy and agreement. However, the analysis of images in the early postoperative period as well as paracentral corneal areas revealed larger variabilities. This revealed that the FFM and ACM counting methods cannot be used interchangeably under all circumstances. The ACM seemed preferable when only low-quality images were available and permitted determination of additional qualitative endothelial cell parameters.

Entities:  

Mesh:

Year:  2005        PMID: 15725880     DOI: 10.1097/01.ico.0000141234.48967.e3

Source DB:  PubMed          Journal:  Cornea        ISSN: 0277-3740            Impact factor:   2.651


  4 in total

1.  Two single descriptors of endothelial polymegethism and pleomorphism.

Authors:  Jose Manuel González-Méijome; Jorge Jorge; Antonio Queirós; Sofia C Peixoto-de-Matos; Manuel A Parafita
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2010-03-12       Impact factor: 3.117

2.  Prospective Randomized Study Comparing Combined Phaco-ExPress and Phacotrabeculectomy in Open Angle Glaucoma Treatment: 12-Month Follow-Up.

Authors:  Joanna Konopińska; Marta Deniziak; Emil Saeed; Agnieszka Bartczak; Renata Zalewska; Zofia Mariak; Marek Rękas
Journal:  J Ophthalmol       Date:  2015-06-07       Impact factor: 1.909

3.  Endothelial cell loss 5 years after Preserflo MicroShunt implantation: About two cases.

Authors:  Chloé Chamard; Sirine Hammoud; Elisa Bluwol; Yves Lachkar
Journal:  Am J Ophthalmol Case Rep       Date:  2021-12-08

4.  Comparison of Anterior Segment Abnormalities in Individuals With FOXC1 and PITX2 Variants.

Authors:  Mallika Prem Senthil; Lachlan S W Knight; Deepa Taranath; David A Mackey; Jonathan B Ruddle; Mark Y Chiang; Owen M Siggs; Emmanuelle Souzeau; Jamie E Craig
Journal:  Cornea       Date:  2022-03-30       Impact factor: 3.152

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.